ExamPass EngineeringExamPass Engineering Start free
FE Electrical and Computer · Knowledge area 2 of 17

Circuit Analysis (DC and AC Steady State) on the FE Electrical and Computer exam

Circuit Analysis (DC and AC Steady State) accounts for 12 of the 110 questions — 10.9% of your exam. It is one of the three heaviest areas on this paper, so it is worth your study time before almost anything else.

Questions12
Share of exam10.9%
Rank by weight2/17
In our bank39

What Circuit Analysis (DC and AC Steady State) covers

On the FE Electrical and Computer exam this area covers Ohm’s and Kirchhoff’s laws, series and parallel reduction, node and mesh analysis, Thevenin and Norton equivalents, phasors and impedance, resonance, and three-phase circuits.

What the questions look like: An equivalent resistance or impedance, a node voltage, a Thevenin equivalent, or a phasor current.

Worth knowing cold: Thevenin equivalents turn long circuits into short ones. Spotting when to use one is the highest-value skill in this area.

3 free Circuit Analysis (DC and AC Steady State) practice problems

These come from our FE Electrical and Computer bank, written to the same specification as the exam. Try each one before opening the solution.

Problem 1

An AC linear circuit operates in steady state at an angular frequency of $\omega = 1{,}000\text{ rad/s}$ as shown in the schematic. The circuit parameters are: - Independent voltage source: $\mathbf{V}_s = 100\angle 0^\circ\text{ V}$ - Resistor: $R_1 = 20\ \Omega$ - Inductor: $L = 40\text{ mH} \implies j\omega L = +j40\ \Omega$ - Current-controlled voltage source (CCVS): $10\mathbf{I}_x$, where $\mathbf{I}_x$ is the phasor current flowing through resistor $R_1$ - Capacitor: $C = 25\ \mu\text{F} \implies -j/(\omega C) = -j40\ \Omega$ What is the open-circuit Thevenin equivalent voltage phasor $\mathbf{V}_{th}$ across terminals a-b?

  1. A92.2 V (with phase angle +12.5°)correct
  2. B80.0 V (with phase angle +26.6°)
  3. C100.0 V (with phase angle 0.0°)
  4. D114.5 V (with phase angle -18.4°)
Show the solution

**Step 1: Understand Thevenin Voltage Definition in the Frequency Domain** From the FE Reference Handbook (Electrical and Computer / AC Circuit Analysis): The open-circuit Thevenin voltage $\mathbf{V}_{th}$ is the phasor potential difference between open terminals a and b: $$\mathbf{V}_{th} = \mathbf{V}_a - \mathbf{V}_b = \mathbf{V}_{ab(oc)}$$ **Step 2: Determine Mesh Current I_x under Open-Circuit Condition** Because terminals a-b are open-circuited, no current can flow through the rightmost capacitor branch into terminal a: $$\mathbf{I}_{out} = 0$$ Consequently, the source current $\mathbf{I}_x$ flows solely through the series combination of $R_1$ and inductor $L$: $$\mathbf{I}_x = \frac{\mathbf{V}_s}{R_1 + j\omega L} = \frac{100\angle 0^\circ}{20 + j40}\text{ A}$$ Multiplying numerator and denominator by the complex conjugate $(20 - j40)$: $$\mathbf{I}_x = \frac{100(20 - j40)}{20^2 + 40^2} = \frac{2{,}000 - j4{,}000}{2{,}000} = 1.0 - j2.0\text{ A}$$ In polar form: $$|\mathbf{I}_x| = \sqrt{1.0^2 + (-2.0)^2} = \sqrt{5.0} = 2.236\text{ A}, \quad \theta_{Ix} = -\arctan(2.0) = -63.43^\circ$$ **Step 3: Calculate Open-Circuit Voltage across Terminals a-b** Referencing bottom node b to ground ($0\text{ V}$): The node voltage at the junction of $R_1$ and $L$ is: $$\mathbf{V}_1 = (j\omega L) \mathbf{I}_x = (j40)(1.0 - j2.0) = j40 - j^2(80) = 80 + j40\text{ V}$$ Since zero current flows through the capacitor $-j40\ \Omega$, there is zero voltage drop across $C$. The voltage at terminal a is simply $\mathbf{V}_1$ plus the dependent source voltage $10\mathbf{I}_x$: $$\mathbf{V}_{th} = \mathbf{V}_1 + 10\mathbf{I}_x = (80 + j40) + 10(1.0 - j2.0)$$ $$\mathbf{V}_{th} = 80 + j40 + 10 - j20 = 90 + j20\text{ V}$$ **Step 4: Convert V_th to Polar Coordinates** $$|\mathbf{V}_{th}| = \sqrt{90^2 + 20^2} = \sqrt{8{,}100 + 400} = \sqrt{8{,}500} = 92.195\text{ V} \approx 92.2\text{ V}$$ $$\theta_{th} = \arctan\left(\frac{20}{90}\right) = \arctan(0.2222) = +12.53^\circ \approx +12.5^\circ$$ Conclusion: The Thevenin voltage is **92.2 V ∠ +12.5°**. Distractor Analysis: - Option A: with phase angle +12.5° (Correct) - Option B: with phase angle +26.6° - Option C: with phase angle 0.0° - Option D: with phase angle -18.4°

Problem 2

An operational amplifier comparator with positive feedback (inverting Schmitt trigger) is biased as shown in the diagram: - Output saturation voltage rails: $V_{sat+} = +15.0\text{ V}$ and $V_{sat-} = -15.0\text{ V}$ - Feedback resistor: $R_2 = 80.0\text{ k}\Omega$ connected between $v_{out}$ and the non-inverting node $V_+$ - DC bias branch: $R_1 = 20.0\text{ k}\Omega$ connected between $V_+$ and a fixed DC reference $V_{bias} = +5.0\text{ V}$ - Input voltage $v_{in}(t)$ is applied to the inverting input terminal ($-$) What are the upper switching threshold voltage $V_{TH}$ (when transitioning from high to low) and the lower switching threshold voltage $V_{TL}$ (when transitioning from low to high)?

  1. A7.00 V (with lower threshold V_TL = +1.00 V and hysteresis window V_H = 6.00 V)correct
  2. B6.00 V (with lower threshold V_TL = 0.00 V and hysteresis window V_H = 6.00 V)
  3. C8.00 V (with lower threshold V_TL = +2.00 V and hysteresis window V_H = 6.00 V)
  4. D5.00 V (with lower threshold V_TL = -1.00 V and hysteresis window V_H = 6.00 V)
Show the solution

**Step 1: Formulate the Non-Inverting Node Voltage $V_+$** From the FE Reference Handbook (Linear Systems / Operational Amplifiers / Comparators with Hysteresis): Applying nodal analysis (Kirchhoff's Current Law) or superposition at the non-inverting terminal $V_+$ (assuming ideal op-amp input impedance with zero input bias current): $$V_+ = V_{bias} \left( \frac{R_2}{R_1 + R_2} \right) + v_{out} \left( \frac{R_1}{R_1 + R_2} \right)$$ Substituting the given resistor values: $$R_1 + R_2 = 20.0\text{ k}\Omega + 80.0\text{ k}\Omega = 100.0\text{ k}\Omega$$ $$\frac{R_2}{R_1 + R_2} = \frac{80.0}{100.0} = 0.800, \quad \beta = \frac{R_1}{R_1 + R_2} = \frac{20.0}{100.0} = 0.200$$ $$V_+ = (5.00\text{ V})(0.800) + 0.200 \cdot v_{out} = 4.00\text{ V} + 0.200 \cdot v_{out}$$ **Step 2: Calculate Upper Threshold $V_{TH}$** When the output is currently saturated at the positive rail, $v_{out} = V_{sat+} = +15.0\text{ V}$: The op-amp will switch to the negative rail when the inverting input $v_{in}$ exceeds $V_+$: $$V_{TH} = V_+(v_{out} = +15.0\text{ V}) = 4.00\text{ V} + 0.200(+15.0\text{ V}) = 4.00\text{ V} + 3.00\text{ V} = +7.00\text{ V}$$ **Step 3: Calculate Lower Threshold $V_{TL}$ and Hysteresis $V_H$** When the output is saturated at the negative rail, $v_{out} = V_{sat-} = -15.0\text{ V}$: The op-amp will switch back to the positive rail when $v_{in}$ falls below $V_+$: $$V_{TL} = V_+(v_{out} = -15.0\text{ V}) = 4.00\text{ V} + 0.200(-15.0\text{ V}) = 4.00\text{ V} - 3.00\text{ V} = +1.00\text{ V}$$ The total hysteresis width is: $$V_H = V_{TH} - V_{TL} = 7.00\text{ V} - 1.00\text{ V} = 6.00\text{ V}$$ Conclusion: The switching thresholds are $V_{TH} = \mathbf{+7.00\text{ V}}$ and $V_{TL} = \mathbf{+1.00\text{ V}}$. Distractor Analysis: - Option A: with lower threshold V_TL = +1.00 V and hysteresis window V_H = 6.00 V (Correct) - Option B: with lower threshold V_TL = 0.00 V and hysteresis window V_H = 6.00 V - Option C: with lower threshold V_TL = +2.00 V and hysteresis window V_H = 6.00 V - Option D: with lower threshold V_TL = -1.00 V and hysteresis window V_H = 6.00 V

Problem 3

A balanced three-phase, three-wire, $480.0\text{ V rms}$ (line-to-line), $60\text{ Hz}$ utility service supplies a balanced inductive load. Two wattmeters are connected in the standard two-wattmeter configuration with their current coils in lines A and C, and potential coils connected to common line B ($V_{AB}, I_A$ and $V_{CB}, I_C$). The wattmeters record steady-state readings of: $$W_1 = 12.00\text{ kW}$$ $$W_2 = 4.00\text{ kW}$$ What are the total active three-phase real power $P_{3\phi}$ absorbed by the load and the operating power factor $\text{pf}$?

  1. A16.00 kW (with lagging power factor pf = 0.756)correct
  2. B8.00 kW (power difference error)
  3. C24.00 kW (unscaled sum error)
  4. D12.00 kW (reading single meter)
Show the solution

**Step 1: Calculate Total 3-Phase Real Power $P_{3\phi}$** From the FE Reference Handbook (Circuit Analysis / Three-Phase / Two-Wattmeter Method): The total three-phase real active power delivered to any balanced three-wire load is the algebraic sum of both wattmeter readings: $$P_{3\phi} = W_1 + W_2 = 12.00\text{ kW} + 4.00\text{ kW} = 16.00\text{ kW}$$ **Step 2: Calculate Total 3-Phase Reactive Power $Q_{3\phi}$** The total reactive power in a balanced system measured by two wattmeters is: $$Q_{3\phi} = \sqrt{3}(W_1 - W_2) = \sqrt{3}(12.00\text{ kW} - 4.00\text{ kW}) = \sqrt{3}(8.00\text{ kW}) = 13.8564\text{ kVAR}$$ **Step 3: Calculate Operating Power Factor $\text{pf}$** Using the phase angle formula: $$\tan(\theta) = \sqrt{3} \frac{W_1 - W_2}{W_1 + W_2} = \sqrt{3} \frac{8.00}{16.00} = \frac{\sqrt{3}}{2} = 0.866025$$ $$\theta = \arctan(0.866025) = 40.893^\circ$$ $$\text{pf} = \cos(\theta) = \cos(40.893^\circ) = 0.7559 \approx 0.756\text{ lagging}$$ (Alternatively: $S_{3\phi} = \sqrt{P^2 + Q^2} = \sqrt{16.00^2 + 13.856^2} = 21.166\text{ kVA} \implies \text{pf} = \frac{16.00}{21.166} = 0.7559$). Conclusion: The total real power is **$16.00\text{ kW}$** and the power factor is **$0.756\text{ lagging}$**. Distractor Analysis: - Option A: with lagging power factor pf = 0.756 (Correct) - Option B: power difference error - Option C: unscaled sum error - Option D: reading single meter

Find out where you actually stand

A free 20-question diagnostic across every FE Electrical and Computer knowledge area, scored in the real exam interface. You get a projected score and the areas costing you the most — so you know whether Circuit Analysis (DC and AC Steady State) is where your time should go at all.

Start the free Electrical & Computer diagnostic

Retaking the FE Electrical and Computer exam?

Copy the scores from your NCEES diagnostic report and see whether Circuit Analysis (DC and AC Steady State) is where your next attempt gains the most points, or whether another area deserves the time first.

Analyze my diagnostic report

Other FE Electrical and Computer knowledge areas