ExamPass EngineeringExamPass Engineering Start free
FE Other Disciplines · Knowledge area 14 of 14

Instrumentation and Controls on the FE Other Disciplines exam

Instrumentation and Controls accounts for 4 of the 110 questions — 3.6% of your exam. It is one of the lighter areas, which makes it a good place to secure quick marks rather than a place to spend weeks.

Questions4
Share of exam3.6%
Rank by weight14/14
In our bank18

What Instrumentation and Controls covers

On the FE Other Disciplines exam this area covers sensors and transducers, signal conditioning, measurement error and uncertainty, calibration, data acquisition, and feedback control fundamentals.

What the questions look like: An error or uncertainty computation, a sensor output, or a control-loop behaviour question.

Worth knowing cold: Distinguish accuracy, precision and resolution. Questions here often turn entirely on that distinction.

3 free Instrumentation and Controls practice problems

These come from our FE Other Disciplines bank, written to the same specification as the exam. Try each one before opening the solution.

Problem 1

A seismic piezoelectric accelerometer modeled as a linear second-order dynamic transducer has an undamped natural frequency of $f_n = 20.0\text{ kHz}$ and a damping ratio of $\zeta = 0.650$. The instrument measures sinusoidal harmonic vibration at an excitation frequency of $f = 6.00\text{ kHz}$. What are the dynamic amplitude magnification ratio $M$ and the phase lag angle $\phi$?

  1. A0.950 (underestimating amplitude error)
  2. B1.010 (with phase lag phi = 23.2° and +1.0% dynamic amplitude error)correct
  3. C1.150 (resonant peaking error)
  4. D0.820 (omitting damping term)
Show the solution

**Step 1: Compute Dimensionless Frequency Ratio** From the FE Reference Handbook (Measurement, Instrumentation, and Controls / Dynamic Response of Second-Order Instruments): $$u = \frac{f}{f_n} = \frac{6.00\text{ kHz}}{20.0\text{ kHz}} = 0.300$$ **Step 2: Calculate Dynamic Amplitude Magnification Factor $M$** The second-order frequency response magnitude formula is: $$M(u) = \frac{1}{\sqrt{(1 - u^2)^2 + (2\zeta u)^2}}$$ - $1 - u^2 = 1 - (0.300)^2 = 1 - 0.090 = 0.910$ - $(1 - u^2)^2 = (0.910)^2 = 0.8281$ - $2\zeta u = 2(0.650)(0.300) = 0.390$ - $(2\zeta u)^2 = (0.390)^2 = 0.1521$ Sum under square root: $$(1 - u^2)^2 + (2\zeta u)^2 = 0.8281 + 0.1521 = 0.9802$$ $$M = \frac{1}{\sqrt{0.9802}} = \frac{1}{0.99005} = 1.01005 \approx 1.010$$ (Dynamic amplitude error: $(1.01005 - 1) \times 100\% = +1.01\%$). **Step 3: Compute Phase Lag Angle $\phi$** $$\phi = \arctan\left(\frac{2\zeta u}{1 - u^2}\right) = \arctan\left(\frac{0.390}{0.910}\right) = \arctan(0.42857) = 23.199^\circ \approx 23.2^\circ$$ Conclusion: The dynamic amplitude ratio is **$1.010$** with phase lag **$\phi = 23.2^\circ$**.

Problem 2

A precision feedback position servomechanism is modeled as a prototype second-order underdamped closed-loop transfer function: $$T(s) = \frac{\omega_n^2}{s^2 + 2\zeta \omega_n s + \omega_n^2}$$ When excited by a unit step input, the experimental step response reveals a percent peak overshoot $M_p = 16.30\%$ and a peak time $t_p = 0.850\text{ s}$. What is the undamped natural frequency $\omega_n$ (in rad/s) of this control system?

  1. A3.14 rad/s (assuming critically damped transient behavior)
  2. B4.27 rad/s (undamped natural frequency from peak time and damping ratio)correct
  3. C5.50 rad/s (using undamped frequency directly as damped frequency)
  4. D2.14 rad/s (inverting damping factor calculation)
Show the solution

Step 1: Determine the damping ratio $\zeta$ from peak overshoot $M_p$: $$M_p = e^{-\frac{\pi \zeta}{\sqrt{1 - \zeta^2}}} = 0.1630$$ $$\ln(0.1630) = -1.81400$$ $$\frac{\pi \zeta}{\sqrt{1 - \zeta^2}} = 1.81400$$ $$\frac{\zeta}{\sqrt{1 - \zeta^2}} = \frac{1.81400}{\pi} = \frac{1.81400}{3.14159} = 0.57741$$ Squaring both sides: $$\frac{\zeta^2}{1 - \zeta^2} = (0.57741)^2 = 0.33340$$ $$\zeta^2 = 0.33340 (1 - \zeta^2) = 0.33340 - 0.33340 \zeta^2$$ $$1.33340 \zeta^2 = 0.33340 \implies \zeta^2 = \frac{0.33340}{1.33340} = 0.25004$$ $$\zeta = \sqrt{0.25004} = 0.5000$$ Step 2: Relate peak time $t_p$ to damped natural frequency $\omega_d$: $$t_p = \frac{\pi}{\omega_d} = \frac{\pi}{\omega_n \sqrt{1 - \zeta^2}}$$ $$\sqrt{1 - \zeta^2} = \sqrt{1 - (0.500)^2} = \sqrt{0.750} = 0.86603$$ Step 3: Solve for undamped natural frequency $\omega_n$: $$\omega_n = \frac{\pi}{t_p \sqrt{1 - \zeta^2}} = \frac{3.14159\text{ rad}}{(0.850\text{ s})(0.86603)} = \frac{3.14159}{0.73613} = 4.2677\text{ rad/s} \approx 4.27\text{ rad/s}$$ Therefore, the undamped natural frequency is 4.27 rad/s (option B).

Problem 3

A standard prototype second-order closed-loop positioning feedback control system has the closed-loop transfer function: T(s) = 100.0 / [ s^2 + 12.0*s + 100.0 ] The system is subjected to a unit-step setpoint reference input r(t) = u(t). What is the peak time t_p (in seconds) at which the transient step response reaches its first maximum peak value?

  1. A0.524 s
  2. B0.393 scorrect
  3. C0.285 s
  4. D0.612 s
Show the solution

Step 1 - Standard Second-Order Transfer Function Parameters: Compare the given transfer function with the standard prototype form: $$T(s) = \frac{\omega_n^2}{s^2 + 2 \zeta \omega_n s + \omega_n^2} = \frac{100.0}{s^2 + 12.0 s + 100.0}$$ - Natural frequency: $$\omega_n^2 = 100.0 \implies \omega_n = 10.00\text{ rad/s}$$ - Damping ratio $\zeta$: $$2 \zeta \omega_n = 12.0 \implies 2 \zeta (10.00) = 12.0 \implies \zeta = \frac{12.0}{20.0} = 0.600$$ Since $0 < \zeta < 1.0$, the transient response is underdamped. Step 2 - Damped Natural Frequency ($\omega_d$): $$\omega_d = \omega_n \sqrt{1 - \zeta^2} = 10.00 \sqrt{1 - (0.600)^2} = 10.00 \sqrt{1 - 0.360} = 10.00 \sqrt{0.640} = 10.00(0.800) = 8.000\text{ rad/s}$$ Step 3 - Calculate Peak Time ($t_p$): For an underdamped second-order step response, the first peak occurs at: $$t_p = \frac{\pi}{\omega_d} = \frac{\pi}{8.000\text{ rad/s}} = 0.39270\text{ s} \approx 0.393\text{ s}$$ Therefore, the peak time is 0.393 s (Option B).

Find out where you actually stand

A free 20-question diagnostic across every FE Other Disciplines knowledge area, scored in the real exam interface. You get a projected score and the areas costing you the most — so you know whether Instrumentation and Controls is where your time should go at all.

Start the free Other Disciplines diagnostic

Retaking the FE Other Disciplines exam?

Copy the scores from your NCEES diagnostic report and see whether Instrumentation and Controls is where your next attempt gains the most points, or whether another area deserves the time first.

Analyze my diagnostic report

Other FE Other Disciplines knowledge areas