A seismic piezoelectric accelerometer modeled as a linear second-order dynamic transducer has an undamped natural frequency of $f_n = 20.0\text{ kHz}$ and a damping ratio of $\zeta = 0.650$. The instrument measures sinusoidal harmonic vibration at an excitation frequency of $f = 6.00\text{ kHz}$. What are the dynamic amplitude magnification ratio $M$ and the phase lag angle $\phi$?
- A0.950 (underestimating amplitude error)
- B1.010 (with phase lag phi = 23.2° and +1.0% dynamic amplitude error)correct
- C1.150 (resonant peaking error)
- D0.820 (omitting damping term)
Show the solution
**Step 1: Compute Dimensionless Frequency Ratio** From the FE Reference Handbook (Measurement, Instrumentation, and Controls / Dynamic Response of Second-Order Instruments): $$u = \frac{f}{f_n} = \frac{6.00\text{ kHz}}{20.0\text{ kHz}} = 0.300$$ **Step 2: Calculate Dynamic Amplitude Magnification Factor $M$** The second-order frequency response magnitude formula is: $$M(u) = \frac{1}{\sqrt{(1 - u^2)^2 + (2\zeta u)^2}}$$ - $1 - u^2 = 1 - (0.300)^2 = 1 - 0.090 = 0.910$ - $(1 - u^2)^2 = (0.910)^2 = 0.8281$ - $2\zeta u = 2(0.650)(0.300) = 0.390$ - $(2\zeta u)^2 = (0.390)^2 = 0.1521$ Sum under square root: $$(1 - u^2)^2 + (2\zeta u)^2 = 0.8281 + 0.1521 = 0.9802$$ $$M = \frac{1}{\sqrt{0.9802}} = \frac{1}{0.99005} = 1.01005 \approx 1.010$$ (Dynamic amplitude error: $(1.01005 - 1) \times 100\% = +1.01\%$). **Step 3: Compute Phase Lag Angle $\phi$** $$\phi = \arctan\left(\frac{2\zeta u}{1 - u^2}\right) = \arctan\left(\frac{0.390}{0.910}\right) = \arctan(0.42857) = 23.199^\circ \approx 23.2^\circ$$ Conclusion: The dynamic amplitude ratio is **$1.010$** with phase lag **$\phi = 23.2^\circ$**.