A horizontal commercial steel pipeline (equivalent sand roughness $\varepsilon = 0.045\text{ mm} = 4.5 \times 10^{-5}\text{ m}$) has an internal diameter of $D = 150.0\text{ mm} = 0.150\text{ m}$ and length $L = 250.0\text{ m}$. Water (density $\rho = 1000\text{ kg/m}^3$, kinematic viscosity $\nu = 1.00 \times 10^{-6}\text{ m}^2/\text{s}$) flows through the pipe at a volumetric discharge of $Q = 0.0530\text{ m}^3/\text{s} = 53.0\text{ L/s}$. Using the Swamee-Jain explicit approximation to the Colebrook equation: What are the Darcy friction factor $f$ and total friction head loss $h_f$?
- A0.0083 (half friction factor error)
- B0.0331 (double friction factor error)
- C0.0248 (smooth pipe assumption error)
- D0.0165 (with head loss h_f = 12.6 m and pressure drop Delta P = 124 kPa)correct
Show the solution
**Step 1: Compute Flow Velocity and Reynolds Number** From the FE Reference Handbook (Fluid Mechanics / Incompressible Flow / Darcy-Weisbach Equation): - Pipe cross-sectional area: $$A = \frac{\pi}{4} D^2 = \frac{\pi}{4} (0.150\text{ m})^2 = 0.017671\text{ m}^2$$ - Mean velocity: $$V = \frac{Q}{A} = \frac{0.0530\text{ m}^3/\text{s}}{0.017671\text{ m}^2} = 2.9993\text{ m/s} \approx 3.00\text{ m/s}$$ - Reynolds number: $$Re = \frac{V D}{\nu} = \frac{(3.00\text{ m/s})(0.150\text{ m})}{1.00 \times 10^{-6}\text{ m}^2/\text{s}} = 450{,}000 = 4.50 \times 10^5\quad (\text{Turbulent flow})$$ **Step 2: Determine Darcy Friction Factor $f$** - Relative roughness: $$\frac{\varepsilon}{D} = \frac{0.045\text{ mm}}{150.0\text{ mm}} = 0.000300$$ Using the Swamee-Jain equation: $$f = \frac{0.25}{\left[\log_{10}\left(\frac{\varepsilon / D}{3.7} + \frac{5.74}{Re^{0.9}}\right)\right]^2}$$ $$\frac{\varepsilon / D}{3.7} = \frac{0.000300}{3.7} = 8.1081 \times 10^{-5}$$ $$\frac{5.74}{Re^{0.9}} = \frac{5.74}{(450{,}000)^{0.9}} = \frac{5.74}{118{,}154} = 4.8581 \times 10^{-5}$$ $$\text{Sum} = 8.1081 \times 10^{-5} + 4.8581 \times 10^{-5} = 1.29662 \times 10^{-4}$$ $$\log_{10}(1.29662 \times 10^{-4}) = -3.88719$$ $$f = \frac{0.25}{(-3.88719)^2} = \frac{0.25}{15.1102} = 0.016545 \approx 0.0165$$ **Step 3: Calculate Head Loss $h_f$ and Pressure Drop $\Delta P$** $$h_f = f \frac{L}{D} \frac{V^2}{2g} = (0.016545) \times \frac{250.0\text{ m}}{0.150\text{ m}} \times \frac{(3.00\text{ m/s})^2}{2(9.81\text{ m/s}^2)} = (0.016545) \times 1666.67 \times 0.45872 = 12.648\text{ m} \approx 12.6\text{ m}$$ $$\Delta P = \rho g h_f = (1000\text{ kg/m}^3)(9.81\text{ m/s}^2)(12.648\text{ m}) = 124{,}077\text{ Pa} = 124.1\text{ kPa}$$ Conclusion: The friction factor is **$0.0165$** and head loss is **$12.6\text{ m}$**.