A venturi meter reduces a pipe from 300 mm to 150 mm diameter. A mercury manometer (specific gravity 13.6) connected across the throat registers a reading of 0.50 m, with water (specific gravity 1.0) as the flowing fluid. Neglecting losses, what is the flow rate through the pipe?
- A0.1965 m³/s, omitting the velocity-of-approach correction for the upstream area
- B0.0572 m³/s, using the raw manometer reading instead of the equivalent head of water
- C0.8117 m³/s, using the upstream pipe area instead of the throat area
- D0.2029 m³/scorrect
Show the solution
First convert the manometer reading to an equivalent head difference, then combine continuity and Bernoulli's equation. Head difference: Δh = R(SG manometer fluid /SG flowing fluid − 1) = 0.50(13.6/1.0 − 1) = 0.50(12.6) = 6.3 m. Continuity: A₁V₁ = A₂V₂, with area ratio A₂/A₁ = (150/300)² = 0.25, so V₁ = 0.25V₂. Bernoulli between the two sections: Δh = (V₂² − V₁²)/(2g) = V₂²(1 − 0.25²)/(2g). V₂² = 2gΔh/(1−0.0625) = 2(9.81)(6.3)/0.9375 = 123.6/0.9375 = 131.86 → V₂ = 11.48 m/s. Q = V₂A₂ = 11.48 × (π/4)(0.150)² = 11.48 × 0.01767 = 0.2029 m³/s. Sanity check: the mercury-over-water manometer multiplies a modest 0.5 m reading into a 6.3 m equivalent water head, which is why venturi meters can register strong, easily readable deflections even from fairly modest actual flows — exactly why mercury manometers were historically preferred for this kind of measurement.