ExamPass EngineeringExamPass Engineering Start free
FE Civil · Knowledge area 1 of 18

Geotechnical Engineering on the FE Civil exam

Geotechnical Engineering accounts for 10 of the 110 questions — 9.1% of your exam. It is one of the three heaviest areas on this paper, so it is worth your study time before almost anything else.

Questions10
Share of exam9.1%
Rank by weight1/18
In our bank37

What Geotechnical Engineering covers

On the FE Civil exam this area covers index properties and soil classification, phase relationships, effective stress, permeability and seepage, consolidation and settlement, shear strength, lateral earth pressure, bearing capacity, slope stability, and shallow and deep foundations.

What the questions look like: A phase-relationship computation, an active or passive earth pressure, a bearing capacity check, or a consolidation settlement.

Worth knowing cold: Phase relationships feed half the area. Being able to move between void ratio, water content, unit weight and degree of saturation without thinking pays for itself.

3 free Geotechnical Engineering practice problems

These come from our FE Civil bank, written to the same specification as the exam. Try each one before opening the solution.

Problem 1

A 2 m × 2 m square footing is placed at a depth of 1.5 m in a soil with cohesion c = 25 kPa, friction angle φ = 25° (Terzaghi bearing capacity factors N c = 25.1, N q = 12.7, N γ = 9.7), and unit weight γ = 18 kN/m³. The footing carries a column load of 900 kN, giving an applied pressure of 225 kPa. Using a required factor of safety of 3.0 against bearing capacity failure, what is the allowable bearing pressure, and does the footing design satisfy the requirement?

  1. A142.9 kPa — fails, applied pressure exceeds this
  2. B381.7 kPa — passes, applied pressure is below thiscorrect
  3. C572.5 kPa — passes, applied pressure is below this
  4. D1,145 kPa — passes, applied pressure is below this
Show the solution

Find the ultimate bearing capacity using all three Terzaghi terms, divide by the required factor of safety, and compare against the applied pressure. q ult = cN c + γD f N q + 0.5γBN γ . q ult = 25(25.1) + 18(1.5)(12.7) + 0.5(18)(2)(9.7) = 627.5 + 342.9 + 174.6 = 1,145 kPa. q allow = q ult /FS = 1,145/3.0 = 381.7 kPa. Applied pressure: q applied = P/A = 900/(2×2) = 225 kPa. Since 225 kPa < 381.7 kPa, the design satisfies the bearing capacity requirement with margin to spare. Options (A) and (C) both misstate the comparison (A inverts the inequality direction, C compares applied pressure to the wrong, un-factored value); (D) is a distractor about methodology that doesn't change the correct numerical conclusion.

Problem 2

A geotechnical laboratory runs several different tests on samples recovered from one borehole. Match each laboratory test to the soil property it is run to measure.

Show the solution

Each of these tests exists because a different design question needs a different measured property, and knowing which test produces which number is what lets an engineer specify a sensible laboratory program instead of ordering everything. The PROCTOR TEST compacts soil at a series of water contents to find the density peak and the moisture that achieves it, which is what a compaction specification is written against in the field. The CONSOLIDATION TEST loads a confined sample in increments and tracks its compression over time, yielding both how much settlement to expect and how long it will take — two separate answers from one test. The DIRECT SHEAR TEST forces failure along a predetermined horizontal plane under several normal stresses, and the resulting failure envelope gives the friction angle and cohesion used in bearing capacity and slope stability calculations. The CONSTANT-HEAD PERMEAMETER maintains a fixed head across a sample and measures the flow through it, suiting coarse soils where flow is fast enough to measure directly (fine soils need the falling-head variant instead). The two unused labels describe the plastic limit and the void ratio — real properties, but neither is what these four tests are run to obtain.

Problem 3

A shallow rectangular concrete spread footing of width B = 2.50 m and length L = 5.00 m transmits a net uniform contact pressure of q0 = 180.0 kPa to a thick, semi-infinite saturated elastic clay deposit. The geotechnical elastic properties of the soil stratum are: - Modulus of elasticity: Es = 25.0 MPa (25,000 kPa) - Poisson's ratio: mu = 0.30 - Rigidity and foundation shape influence factor: Is = 1.20 According to Timoshenko and Goodier elastic settlement formulation (NCEES FE Reference Handbook): Se = [ q0 * B * (1 - mu²) * Is ] / Es (where q0 and Es are in kPa, B is in meters, and Se is in meters). Refer to the accompanying technical diagram [FE-CIV-1759]. What is the immediate elastic settlement Se (in mm) of this foundation?

  1. A12.4 mm
  2. B24.8 mm
  3. C15.6 mm
  4. D19.7 mmcorrect
Show the solution

Step 1 - Elastic Settlement Formulation: Under the theory of elasticity for a surface foundation on an isotropic elastic half-space: $$S_e = \frac{q_0 \cdot B \cdot (1 - \mu^2) \cdot I_s}{E_s}$$ where: - Net foundation contact pressure: $q_0 = 180.0\text{ kPa}$ - Characteristic footing dimension: $B = 2.50\text{ m}$ - Soil Poisson's ratio: $\mu = 0.30$ - Rigidity and shape factor: $I_s = 1.20$ - Soil elastic modulus: $E_s = 25.0\text{ MPa} = 25,000\text{ kPa}$ Step 2 - Evaluate Intermediate Elastic Factor ($1 - \mu^2$): $$1 - \mu^2 = 1 - (0.30)^2 = 1 - 0.090 = 0.910$$ Step 3 - Compute Immediate Settlement ($S_e$): $$S_e = \frac{(180.0\text{ kPa})(2.50\text{ m})(0.910)(1.20)}{25,000\text{ kPa}}$$ $$\text{Numerator} = 180.0 \times 2.50 \times 0.910 \times 1.20 = 491.40\text{ kN/m}$$ $$S_e = \frac{491.40}{25,000} = 0.019656\text{ m}$$ Converting to millimeters ($1\text{ m} = 1,000\text{ mm}$): $$S_e = 0.019656 \times 1,000 = 19.656\text{ mm} \approx 19.7\text{ mm}$$ Step 4 - Distractor Analysis: - Option A ($12.4\text{ mm}$) results from omitting the shape factor $I_s = 1.20$ or dividing by $(1 - \mu^2)$. - Option B ($24.8\text{ mm}$) results from mistakenly substituting length $L = 5.00\text{ m}$ in place of width $B = 2.50\text{ m}$. - Option C ($15.6\text{ mm}$) results from using $E_s = 30.0\text{ MPa}$ ($491.4 / 30,000 = 16.38\text{ mm}$). Therefore, the immediate elastic settlement is 19.7 mm (Option D).

Find out where you actually stand

A free 20-question diagnostic across every FE Civil knowledge area, scored in the real exam interface. You get a projected score and the areas costing you the most — so you know whether Geotechnical Engineering is where your time should go at all.

Start the free Civil diagnostic

Retaking the FE Civil exam?

Copy the scores from your NCEES diagnostic report and see whether Geotechnical Engineering is where your next attempt gains the most points, or whether another area deserves the time first.

Analyze my diagnostic report