A 2 m × 2 m square footing is placed at a depth of 1.5 m in a soil with cohesion c = 25 kPa, friction angle φ = 25° (Terzaghi bearing capacity factors N c = 25.1, N q = 12.7, N γ = 9.7), and unit weight γ = 18 kN/m³. The footing carries a column load of 900 kN, giving an applied pressure of 225 kPa. Using a required factor of safety of 3.0 against bearing capacity failure, what is the allowable bearing pressure, and does the footing design satisfy the requirement?
- A142.9 kPa — fails, applied pressure exceeds this
- B381.7 kPa — passes, applied pressure is below thiscorrect
- C572.5 kPa — passes, applied pressure is below this
- D1,145 kPa — passes, applied pressure is below this
Show the solution
Find the ultimate bearing capacity using all three Terzaghi terms, divide by the required factor of safety, and compare against the applied pressure. q ult = cN c + γD f N q + 0.5γBN γ . q ult = 25(25.1) + 18(1.5)(12.7) + 0.5(18)(2)(9.7) = 627.5 + 342.9 + 174.6 = 1,145 kPa. q allow = q ult /FS = 1,145/3.0 = 381.7 kPa. Applied pressure: q applied = P/A = 900/(2×2) = 225 kPa. Since 225 kPa < 381.7 kPa, the design satisfies the bearing capacity requirement with margin to spare. Options (A) and (C) both misstate the comparison (A inverts the inequality direction, C compares applied pressure to the wrong, un-factored value); (D) is a distractor about methodology that doesn't change the correct numerical conclusion.