Problem 1
A simply supported beam spans 8 ft and carries a uniform dead load of 2.0 kip/ft and a uniform live load of 3.5 kip/ft. Using LRFD, which load combination governs, and what is the resulting factored moment at midspan?
- AMu ≈ 64 kip-ft, dead-plus-live combination governscorrect
- BMu ≈ 29 kip-ft, dead-only combination governs
- CMu ≈ 29 kip-ft, dead-plus-live combination governs
- DMu ≈ 64 kip-ft, dead-only combination governs
Show the solution
LRFD requires checking every applicable load combination and using the largest factored load. wu(1.4D) = 1.4(2.0 kip/ft) = 2.8 kip/ft. wu(1.2D + 1.6L) = 1.2(2.0) + 1.6(3.5) = 2.4 + 5.6 = 8.0 kip/ft. Since 8.0 > 2.8, the 1.2D + 1.6L combination governs, confirming that live load dominance (not just the presence of dead load) is what decides which combination controls for this beam. For a simply supported beam under a uniform load, the maximum factored moment occurs at midspan and equals Mu = wu*L^2/8. With L = 8 m and wu = 8.0 kip/ft, Mu = 8.0(8)^2/8 = 64 kip-ft.
Problem 2
A steel tension member is connected at each end by a group of bolts through its web. Which limit states must be checked for the member itself under this arrangement? Select the two that apply.
- ALateral-torsional buckling of the member along its length
- BWeb crippling of the member beneath the bolt group
- CYielding on the gross cross-section of the member
- DRupture on the net section through the bolt holes
Show the solution
A tension member has two distinct ways of failing, and both must be checked because either can govern depending on how much material the bolt holes remove. YIELDING ON THE GROSS SECTION is a ductile limit state governing the member's general length, where the full cross-section reaches yield and the member stretches substantially — undesirable but gradual, and therefore allowed a smaller safety margin. RUPTURE ON THE NET SECTION is a brittle limit state at the connection, where the area reduced by the bolt holes reaches ultimate strength and tears with little warning, which is why codes apply a larger resistance factor to it and why the net-section check frequently governs despite the ultimate strength exceeding the yield strength. LATERAL-TORSIONAL BUCKLING cannot occur in a tension member at all: it is a stability failure of members in compression or bending, and tension straightens a member rather than destabilizing it. WEB CRIPPLING is a localized bearing limit state at concentrated transverse loads on a beam web, not a tension limit state — the relevant local check at a bolted connection is instead bearing and tear-out at the bolt holes.
Problem 3
A structural steel plate tension member of width w = 250.0 mm and uniform thickness t = 12.0 mm is subjected to axial tension. The bolted splice connection utilizes 20.0-mm diameter bolts arranged in a staggered pattern. In accordance with AISC 360-16 specifications: - Standard hole diameter: dh = 20.0 mm + 2.0 mm = 22.0 mm - Longitudinal bolt pitch: s = 60.0 mm - Transverse bolt gage: g = 75.0 mm According to AISC 360-16 Section B4.3b, the net width wn along any potential diagonal fracture path crossing multiple staggered holes is given by: wn = w - sum(dh) + sum(s^2 / (4 * g)) Refer to the accompanying technical diagram [FE-CIV-1743]. What is the net cross-sectional area An (in mm²) of the plate along the governing staggered fracture path crossing both bolts?
- A2,472 mm²
- B2,736 mm²
- C2,904 mm²
- D2,616 mm²correct
Show the solution
Step 1 - Geometric Parameters of the Tension Plate Connection: - Plate gross width: $w = 250.0\text{ mm}$ - Plate thickness: $t = 12.0\text{ mm}$ - Bolt diameter: $d_b = 20.0\text{ mm}$ - AISC design hole diameter: $$d_h = 20.0\text{ mm} + 2.0\text{ mm} = 22.0\text{ mm}$$ - Longitudinal pitch: $s = 60.0\text{ mm}$ - Transverse gage: $g = 75.0\text{ mm}$ Step 2 - Stagger Correction Term ($s^2 / 4g$): $$\frac{s^2}{4g} = \frac{(60.0\text{ mm})^2}{4 \times 75.0\text{ mm}} = \frac{3,600\text{ mm}^2}{300.0\text{ mm}} = 12.00\text{ mm}$$ Step 3 - Compute Net Widths Along Potential Failure Paths: - Path 1 (Straight transverse section through 1 hole): $$w_{n,1} = w - d_h = 250.0 - 22.0 = 228.0\text{ mm}$$ - Path 2 (Staggered zigzag path crossing both holes 1 and 2): $$w_{n,2} = w - 2 d_h + \frac{s^2}{4g} = 250.0 - 2(22.0) + 12.0$$ $$w_{n,2} = 250.0 - 44.0 + 12.0 = 218.0\text{ mm}$$ The governing critical failure path is the minimum net width: $$w_n = \min(228.0, 218.0) = 218.0\text{ mm}$$ Step 4 - Calculate Net Cross-Sectional Area ($A_n$): $$A_n = w_n \cdot t = (218.0\text{ mm}) \times (12.0\text{ mm}) = 2,616.0\text{ mm}^2$$ Step 5 - Distractor Analysis: - Option A ($2,472\text{ mm}^2$) results from omitting the AISC $+s^2/(4g)$ stagger relief term ($w_n = 250 - 44 = 206\text{ mm} \implies A_n = 206 \times 12 = 2,472\text{ mm}^2$). - Option B ($2,736\text{ mm}^2$) corresponds to the straight path through a single bolt hole ($228.0 \times 12 = 2,736\text{ mm}^2$). - Option C ($2,904\text{ mm}^2$) results from subtracting bolt diameter $20\text{ mm}$ without adding the $2\text{ mm}$ hole allowance. Therefore, the governing net area is 2,616 mm² (Option D).