An industrial furnace wall has a unit cross-sectional area of $A = 1.00\text{ m}^2$ and consists of three material layers in series: - Layer 1 (inside refractory firebrick): thickness $L_1 = 0.120\text{ m}$, thermal conductivity $k_1 = 1.20\text{ W/(m}\cdot\text{K)}$ - Layer 2 (middle insulating blanket): thickness $L_2 = 0.080\text{ m}$, thermal conductivity $k_2 = 0.080\text{ W/(m}\cdot\text{K)}$ - Layer 3 (outside steel plate casing): thickness $L_3 = 0.010\text{ m}$, thermal conductivity $k_3 = 45.0\text{ W/(m}\cdot\text{K)}$ Hot combustion gas on the inside is at $T_{\infty,1} = 850.0^\circ\text{C}$ with internal convection coefficient $h_1 = 40.0\text{ W/(m}^2\cdot\text{K)}$. Ambient room air on the outside is at $T_{\infty,2} = 30.0^\circ\text{C}$ with external convection coefficient $h_2 = 10.0\text{ W/(m}^2\cdot\text{K)}$. What are the steady-state heat flux $q''$ and the outer steel casing surface temperature $T_{s,2}$?
- A669.3 W/m^2 (with outer casing surface temperature T_s2 = 96.9 °C)correct
- B334.6 W/m^2 (half heat flux error)
- C1,338.6 W/m^2 (neglecting insulation resistance)
- D820.0 W/m^2 (assuming total resistance R = 1.0 error)
Show the solution
**Step 1: Calculate Individual Thermal Resistances per Unit Area** From the FE Reference Handbook (Heat Transfer / Conduction & Convection in Composite Walls): The thermal network includes 2 convection and 3 conduction resistances in series: - Inside convection: $R''_{conv,1} = \frac{1}{h_1} = \frac{1}{40.0} = 0.0250\text{ K}\cdot\text{m}^2/\text{W}$ - Firebrick layer: $R''_{cond,1} = \frac{L_1}{k_1} = \frac{0.120}{1.20} = 0.1000\text{ K}\cdot\text{m}^2/\text{W}$ - Insulation layer: $R''_{cond,2} = \frac{L_2}{k_2} = \frac{0.080}{0.080} = 1.0000\text{ K}\cdot\text{m}^2/\text{W}$ - Steel casing: $R''_{cond,3} = \frac{L_3}{k_3} = \frac{0.010}{45.0} = 0.00022\text{ K}\cdot\text{m}^2/\text{W}$ - Outside convection: $R''_{conv,2} = \frac{1}{h_2} = \frac{1}{10.0} = 0.1000\text{ K}\cdot\text{m}^2/\text{W}$ **Step 2: Calculate Total Thermal Resistance and Heat Flux** $$R''_{total} = R''_{conv,1} + R''_{cond,1} + R''_{cond,2} + R''_{cond,3} + R''_{conv,2}$$ $$R''_{total} = 0.0250 + 0.1000 + 1.0000 + 0.00022 + 0.1000 = 1.22522\text{ K}\cdot\text{m}^2/\text{W}$$ The steady-state heat flux is: $$q'' = \frac{T_{\infty,1} - T_{\infty,2}}{R''_{total}} = \frac{850.0^\circ\text{C} - 30.0^\circ\text{C}}{1.22522\text{ K}\cdot\text{m}^2/\text{W}} = \frac{820.0}{1.22522} = 669.27\text{ W/m}^2 \approx 669.3\text{ W/m}^2$$ **Step 3: Determine Outer Surface Temperature $T_{s,2}$** Applying Newton's law of cooling across the outer convection boundary: $$q'' = h_2 (T_{s,2} - T_{\infty,2}) \implies T_{s,2} = T_{\infty,2} + \frac{q''}{h_2}$$ $$T_{s,2} = 30.0^\circ\text{C} + \frac{669.27\text{ W/m}^2}{10.0\text{ W/(m}^2\cdot\text{K)}} = 30.0 + 66.93 = 96.93^\circ\text{C} \approx 96.9^\circ\text{C}$$ Conclusion: The heat flux is **$669.3\text{ W/m}^2$** and the outer casing temperature is **$96.9^\circ\text{C}$**.