ExamPass EngineeringExamPass Engineering Start free
FE Industrial and Systems · Knowledge area 6 of 13

Quality on the FE Industrial and Systems exam

Quality accounts for 10 of the 110 questions — 9.1% of your exam. It sits in the middle of the paper by weight: too big to skip, not big enough to dominate your plan.

Questions10
Share of exam9.1%
Rank by weight6/13
In our bank36

What Quality covers

On the FE Industrial and Systems exam this area covers statistical process control and control charts, process capability, acceptance sampling, design of experiments, reliability, and quality management systems.

What the questions look like: A control chart limit, a capability index, or a reliability computation.

Worth knowing cold: Capability indices and control limits use the same statistics for different purposes. Keep clear which question is being asked.

3 free Quality practice problems

These come from our FE Industrial and Systems bank, written to the same specification as the exam. Try each one before opening the solution.

Problem 1

A process produces a dimension with a known mean of 50.0 mm and a standard deviation of 2.4 mm. Samples are taken in subgroups of 5. Using $UCL = \bar{x} + 3\dfrac{\sigma}{\sqrt{n}}$ and $LCL = \bar{x} - 3\dfrac{\sigma}{\sqrt{n}}$, what are the control limits for the X-bar chart?

  1. AUCL = 52.4 mm, LCL = 47.6 mm, using 1 standard deviation instead of 3
  2. BUCL = 57.2 mm, LCL = 42.8 mm, using the standard deviation directly without dividing by the square root of the subgroup size
  3. CUCL = 51.07 mm, LCL = 48.93 mm, using a subgroup size of 50 instead of 5
  4. DUCL = 53.22 mm, LCL = 46.78 mmcorrect
Show the solution

Control limits for an X-bar chart are set at three standard errors of the SAMPLE MEAN away from the process mean, not three standard deviations of individual measurements — this distinction is the entire point of using subgroup averages rather than plotting raw individual readings, since averaging reduces variability by a known factor tied to the subgroup size. Standard error of the mean: $\dfrac{\sigma}{\sqrt{n}} = \dfrac{2.4}{\sqrt{5}} = \dfrac{2.4}{2.236} = 1.073$ mm. Three standard errors: $3(1.073) = 3.22$ mm. Control limits: $UCL = 50.0+3.22=53.22$ mm, $LCL = 50.0-3.22=46.78$ mm. These limits define the natural, expected range of subgroup AVERAGES when the process is behaving exactly as it has historically — a point falling outside them signals a likely special-cause variation worth investigating, which is a different and much narrower band than the natural range of individual parts the process produces, since individual parts vary by the full $\sigma=2.4$ mm, not the reduced $1.073$ mm that subgroup averaging achieves.

Problem 2

An automated surface-mount circuit board assembly line monitors soldering bridge nonconformities using an attribute u-chart (nonconformities per inspection unit). Inspection sample lot sizes vary from batch to batch. For inspection subgroup 10, the sample size consists of n₁₀ = 16 circuit boards. Historical baseline monitoring across 30 previous production runs establishes the process centerline average defects per unit as ū = 2.250 defects/board. Calculate the Upper Control Limit for subgroup 10 (UCL₁₀ = ū + 3 · √[ū / n₁₀]) in defects per board. Round your answer to two decimal places.

Show the solution

**Step 1: Identify u-Chart Control Limit Formula** From the NCEES FE Reference Handbook (Quality Control - Control Charts for Attributes): For a $u$-chart with variable sample size $n_i$: $$\text{UCL}_i = \bar{u} + 3 \sqrt{\frac{\bar{u}}{n_i}}$$ $$\text{LCL}_i = \max\left(0, \bar{u} - 3 \sqrt{\frac{\bar{u}}{n_i}}\right)$$ **Step 2: Substitute Known Parameters for Subgroup 10** Given process average $\bar{u} = 2.250$ defects per unit and subgroup size $n_{10} = 16$ units: $$\frac{\bar{u}}{n_{10}} = \frac{2.250}{16} = 0.140625$$ $$\sigma_{u, 10} = \sqrt{0.140625} = \frac{\sqrt{2.250}}{\sqrt{16}} = \frac{1.50}{4.0} = 0.3750$$ **Step 3: Calculate the Upper Control Limit (UCL₁₀)** $$\text{UCL}_{10} = 2.250 + 3(0.3750) = 2.250 + 1.1250 = 3.3750\text{ defects/unit} \approx 3.38\text{ defects/board}$$ **Step 4: Lower Control Limit Check** $$\text{LCL}_{10} = 2.250 - 3(0.3750) = 2.250 - 1.1250 = 1.1250\text{ defects/board}$$ Physical meaning: If subgroup 10 exhibits an average defect density exceeding $3.38$ nonconformities per board, an assignable cause of variation is present. Conclusion: $\text{UCL}_{10} =$ **3.38 defects/board**.

Problem 3

A quality control department monitors riveting defects on commercial aircraft fuselage panels. Across 20 inspected panels of standard unit surface area, a total of 180 defects are recorded in statistical control (c̄ = 9.0 defects/panel). An oversized cargo door panel having an inspection surface area equivalent to n_i = 2.25 standard units is inspected, revealing 28 riveting defects. Using an attribute u-chart for varying inspection unit sizes, calculate the Upper Control Limit (UCL_u) for the oversized cargo door panel and determine its process control status.

  1. A18.0 defects/unit and the process is out of control (Exceeds standard c-chart UCL)
  2. B15.0 defects/unit and the process is in control (Observed rate u = 12.44 is below UCL)correct
  3. C12.0 defects/unit and the process is out of control (Observed rate u = 12.44 exceeds UCL)
  4. D21.5 defects/unit and the process is in control (Using sample variance approximation)
Show the solution

**Step 1: Determine Baseline Defect Density (ū)** From the FE Reference Handbook (Quality / Attribute Control Charts): For Poisson defect occurrences across standard inspection units: $$\bar{u} = \bar{c} = \frac{180\text{ defects}}{20\text{ standard panels}} = 9.0\text{ defects/unit}$$ **Step 2: Formulate u-Chart Control Limits for Subgroup Size n_i = 2.25** When inspection subgroup size varies ($n_i \ne 1$), the standard error of defects per unit is: $$\sigma_{u_i} = \sqrt{\frac{\bar{u}}{n_i}} = \sqrt{\frac{9.0}{2.25}} = \sqrt{4.0} = 2.0\text{ defects/unit}$$ The 3-sigma Upper Control Limit is: $$\text{UCL}_{u_i} = \bar{u} + 3 \sigma_{u_i} = 9.0 + 3(2.0) = 9.0 + 6.0 = 15.0\text{ defects/unit}$$ $$\text{LCL}_{u_i} = \max[0, \bar{u} - 3 \sigma_{u_i}] = \max[0, 9.0 - 6.0] = 3.0\text{ defects/unit}$$ **Step 3: Evaluate Observed Panel Quality Against UCL** For the inspected oversized door panel ($x_i = 28$ defects across $n_i = 2.25$ units): $$u_i = \frac{x_i}{n_i} = \frac{28\text{ defects}}{2.25\text{ units}} = 12.444\text{ defects/unit}$$ Comparing to control limits: $$\text{LCL}_{u_i} (3.0) \le u_i (12.44) \le \text{UCL}_{u_i} (15.0)$$ Because the observed defect rate is strictly within control limits, the process remains in statistical control. Conclusion: The limit and status are **15.0 defects/unit and the process is in control** (Option B).

Find out where you actually stand

A free 20-question diagnostic across every FE Industrial and Systems knowledge area, scored in the real exam interface. You get a projected score and the areas costing you the most — so you know whether Quality is where your time should go at all.

Start the free Industrial & Systems diagnostic

Retaking the FE Industrial and Systems exam?

Copy the scores from your NCEES diagnostic report and see whether Quality is where your next attempt gains the most points, or whether another area deserves the time first.

Analyze my diagnostic report

Other FE Industrial and Systems knowledge areas