Problem 1
An irreversible liquid-phase reaction $A \to B$ is carried out isothermally with an entering volumetric flow rate $v_0 = 0.50\text{ m}^3/\text{min}$ and initial concentration $C_{A0} = 2.0\text{ kmol/m}^3$. The Levenspiel plot ($F_{A0}/(-r_A)$ in $\text{m}^3$ versus conversion $X$) obtained from pilot data is shown. The required reactor volume for a single Continuous Stirred-Tank Reactor (CSTR) to achieve $80\%$ conversion ($X = 0.80$) is most nearly:
- A8.8 m³
- B11.2 m³
- C14.4 m³correct
- D18.0 m³
Show the solution
Step 1: Identify the CSTR design equation from the FE Reference Handbook: $$V_{CSTR} = \dfrac{F_{A0} \cdot X}{(-r_A)_{exit}} = X \cdot \left[\dfrac{F_{A0}}{-r_A}\right]_{exit}$$ In a Levenspiel plot, the required CSTR volume is equal to the area of the rectangle of width $X$ and height $[F_{A0}/(-r_A)]_{at\,X}$. Step 2: Read the value of $F_{A0}/(-r_A)$ at the target conversion $X = 0.80$ from the diagram: At $X = 0.80$, the curve reaches: $$\left[\dfrac{F_{A0}}{-r_A}\right]_{X=0.80} = 18.0\text{ m}^3$$ Step 3: Calculate the CSTR volume: $$V_{CSTR} = 0.80 \times 18.0\text{ m}^3 = 14.40\text{ m}^3$$ Step 4: Comparison with PFR volume (area under the curve): Using Simpson's rule over $[0, 0.80]$ with $X_0=0$ (4.0), $X_1=0.40$ (7.0), $X_2=0.80$ (18.0): $$V_{PFR} \approx \dfrac{0.40}{3} [4.0 + 4(7.0) + 18.0] = \dfrac{0.40}{3} [50.0] = 6.67\text{ m}^3$$ As expected for positive-order kinetics, $V_{CSTR} (14.4\text{ m}^3) > V_{PFR} (6.67\text{ m}^3)$. Distractor Analysis: - Option A (8.8 m³) calculates the average between PFR and CSTR volumes. - Option B (11.2 m³) uses the trapezoidal approximation between inlet and outlet. - Option D (18.0 m³) fails to multiply by the conversion $X = 0.80$, reporting the height of the Levenspiel curve.
Problem 2
An isothermal, constant-density liquid-phase reaction $A \rightarrow R$ follows second-order kinetics with rate law $-r_A = k C_{A0}^2 (1 - X_A)^2$, where $k C_{A0}^2 = 0.50\text{ kmol}/(\text{m}^3\cdot\text{s})$. The inlet molar feed rate is $F_{A0} = 5.0\text{ mol/s} = 0.0050\text{ kmol/s}$. The target conversion is $X_A = 0.80$ as shown on the Levenspiel plot. The difference in active reactor volume required between a single continuous stirred tank reactor (CSTR) and a single plug flow reactor (PFR), $(V_{CSTR} - V_{PFR}$, in liters), is most nearly:
- A60 L
- B100 L
- C160 Lcorrect
- D240 L
Show the solution
Step 1: Evaluate the reaction rate at the exit conversion $X_A = 0.80$: $$-r_A = k C_{A0}^2 (1 - X_A)^2 = (0.50\text{ kmol}/(\text{m}^3\cdot\text{s})) (1 - 0.80)^2$$ $$-r_A = 0.50 \times (0.20)^2 = 0.50 \times 0.040 = 0.020\text{ kmol}/(\text{m}^3\cdot\text{s})$$ $$\frac{1}{-r_A} = \frac{1}{0.020} = 50.0\text{ m}^3\cdot\text{s/kmol}$$ Step 2: Calculate the CSTR volume ($V_{CSTR}$): $$V_{CSTR} = F_{A0} \left( \frac{X_A}{-r_A} \right) = (0.0050\text{ kmol/s}) \times (0.80) \times (50.0\text{ m}^3\cdot\text{s/kmol})$$ $$V_{CSTR} = 0.200\text{ m}^3 = 200\text{ L}$$ Step 3: Calculate the PFR volume ($V_{PFR}$): $$V_{PFR} = F_{A0} \int_0^{X_A} \frac{dX_A}{-r_A} = \frac{F_{A0}}{k C_{A0}^2} \int_0^{0.80} \frac{dX_A}{(1 - X_A)^2}$$ $$\int_0^{0.80} \frac{dX_A}{(1 - X_A)^2} = \left[ \frac{1}{1 - X_A} \right]_0^{0.80} = \frac{1}{0.20} - 1 = 5 - 1 = 4.0$$ $$V_{PFR} = \frac{0.0050\text{ kmol/s}}{0.50\text{ kmol}/(\text{m}^3\cdot\text{s})} \times 4.0 = (0.010\text{ m}^3)(4.0) = 0.040\text{ m}^3 = 40\text{ L}$$ Step 4: Compute the volume difference: $$V_{CSTR} - V_{PFR} = 200\text{ L} - 40\text{ L} = 160\text{ L}$$ Distractor Analysis: - Option A (60 L): Evaluates for first-order reaction kinetics. - Option B (100 L): Miscalculates CSTR volume by forgetting the factor of $1/(1 - X_A)^2$. - Option C (160 L): Correct. - Option D (240 L): Adds volumes together ($200 + 40 = 240\text{ L}$).
Problem 3
An irreversible liquid-phase dimerization $A \rightarrow B$ follows second-order kinetics ($-r_A = k C_A^2$, with constant fluid density and feed concentration $C_{A0}$). The reaction is to achieve a fractional conversion of $X_A = 0.800$ ($80.0\%$). From the Levenspiel design equations for isothermal ideal reactors in the NCEES FE Reference Handbook ($V_{CSTR} = \frac{F_{A0} X_A}{(-r_A)_{exit}}$ and $V_{PFR} = F_{A0} \int_0^{X_A} \frac{dX_A}{-r_A}$), the ratio of required reactor volumes ($V_{CSTR} / V_{PFR}$) is:
- AVCSTR / VPFR = 2.50
- BVCSTR / VPFR = 5.00correct
- CVCSTR / VPFR = 8.00
- DVCSTR / VPFR = 12.5
Show the solution
Step 1: Express the second-order reaction rate in terms of conversion ($X_A$) from the NCEES FE Reference Handbook: $$C_A = C_{A0} (1 - X_A) \implies -r_A = k C_{A0}^2 (1 - X_A)^2$$ Step 2: Formulate the CSTR volume requirement at $X_A = 0.800$: $$V_{CSTR} = \frac{F_{A0} X_A}{(-r_A)_{exit}} = \frac{F_{A0} (0.800)}{k C_{A0}^2 (1 - 0.800)^2} = \frac{F_{A0}}{k C_{A0}^2} \times \frac{0.800}{(0.200)^2} = \frac{F_{A0}}{k C_{A0}^2} \times \frac{0.800}{0.0400} = 20.00 \left(\frac{F_{A0}}{k C_{A0}^2}\right)$$ Step 3: Formulate the PFR volume requirement by integration: $$V_{PFR} = F_{A0} \int_0^{X_A} \frac{dX_A}{k C_{A0}^2 (1 - X_A)^2} = \frac{F_{A0}}{k C_{A0}^2} \left[ \frac{1}{1 - X_A} \right]_0^{0.800} = \frac{F_{A0}}{k C_{A0}^2} \left( \frac{1}{0.200} - 1.0 \right) = 4.00 \left(\frac{F_{A0}}{k C_{A0}^2}\right)$$ Step 4: Compute the volume ratio: $$\frac{V_{CSTR}}{V_{PFR}} = \frac{20.00}{4.00} = 5.00$$ Distractor Analysis: - Option A: Evaluates first-order kinetics volume ratio ($\frac{0.8 / 0.2}{\ln(1/0.2)} = \frac{4}{1.609} = 2.49$). - Option B: Correct. - Option C: Squares the conversion ratio ($0.8^2 / 0.2^2$). - Option D: Uses $1/(1-X)^2 = 25 / 2 = 12.5$.