A continuous biological fermenter (chemostat) operates at steady state with sterile feed containing glucose substrate at $S_0 = 15.0\text{ g/L}$. Cell growth follows Monod kinetics with maximum specific growth rate $\mu_{max} = 0.400\text{ hr}^{-1}$, half-saturation constant $K_s = 0.250\text{ g/L}$, and biomass yield coefficient $Y_{X/S} = 0.450\text{ g cells / g substrate}$. Endogenous cell death is negligible. If the chemostat is operated at a dilution rate of $D = 0.300\text{ hr}^{-1}$, the steady-state biomass concentration in the effluent is most nearly:
- A4.50 g/L
- B5.82 g/L
- C6.41 g/Lcorrect
- D7.25 g/L
Show the solution
Step 1: Apply the steady-state biomass balance for a chemostat: $$\dfrac{dX}{dt} = 0 = (\mu - D) X \implies \mu = D = 0.300\text{ hr}^{-1}$$ Step 2: Solve the Monod equation for the steady-state substrate concentration $S$: $$\mu = \dfrac{\mu_{max} S}{K_s + S} \implies 0.300 = \dfrac{0.400 S}{0.250 + S}$$ $$0.300(0.250 + S) = 0.400 S$$ $$0.0750 + 0.300 S = 0.400 S \implies 0.100 S = 0.0750 \implies S = 0.750\text{ g/L}$$ Step 3: Apply the steady-state substrate balance to determine biomass concentration $X$: $$D (S_0 - S) - \dfrac{\mu X}{Y_{X/S}} = 0$$ Since $\mu = D$: $$X = Y_{X/S} (S_0 - S)$$ $$X = 0.450 \times (15.0 - 0.750) = 0.450 \times 14.25 = 6.4125\text{ g/L} \approx 6.41\text{ g/L}$$ Distractor Analysis: - Option A (4.50 g/L) ignores the unconsumed substrate, calculating $X = Y_{X/S} \times 10.0$. - Option B (5.82 g/L) subtracts $K_s$ instead of $S$ from $S_0$: $0.45(15.0 - 2.08) = 5.82$. - Option D (7.25 g/L) assumes 100% conversion of substrate without residual $S$: $0.45 \times 15.0 = 6.75$ plus rounding errors.