Problem 1
A 1-shell-pass, 2-tube-pass heat exchanger is used to cool a hot organic chemical stream from $160^\circ\text{C}$ to $90^\circ\text{C}$ using cooling water that enters the tubes at $25^\circ\text{C}$ and exits at $65^\circ\text{C}$. The heat capacity rate of the hot stream is $C_h = 18.0\text{ kW/K}$ and the overall heat transfer coefficient is $U = 450\text{ W/(m}^2\cdot\text{K)}$. Taking into account the geometry correction factor $F$, the required heat transfer surface area is most nearly:
- A28.4 m²
- B35.4 m²
- C38.5 m²correct
- D47.2 m²
Show the solution
Step 1: Calculate the heat duty of the exchanger: $$Q = C_h (T_{h,in} - T_{h,out}) = 18.0\text{ kW/K} \times (160 - 90)^\circ\text{C} = 18.0 \times 70 = 1,260\text{ kW} = 1,260,000\text{ W}$$ Step 2: Determine the pure countercurrent log-mean temperature difference ($LMTD_{cf}$): $$\Delta T_1 = T_{h,in} - T_{c,out} = 160 - 65 = 95^\circ\text{C}$$ $$\Delta T_2 = T_{h,out} - T_{c,in} = 90 - 25 = 65^\circ\text{C}$$ $$LMTD_{cf} = \dfrac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} = \dfrac{95 - 65}{\ln(95/65)} = \dfrac{30}{\ln(1.4615)} = \dfrac{30}{0.37949} = 79.05^\circ\text{C}$$ Step 3: Determine the dimensionless ratios $P$ and $R$ and correction factor $F$ for a 1-2 exchanger: $$P = \dfrac{t_2 - t_1}{T_1 - t_1} = \dfrac{65 - 25}{160 - 25} = \dfrac{40}{135} = 0.2963$$ $$R = \dfrac{T_1 - T_2}{t_2 - t_1} = \dfrac{160 - 90}{65 - 25} = \dfrac{70}{40} = 1.750$$ From the FE Reference Handbook 1-2 shell-and-tube correction factor chart/formula: $$F = \dfrac{\sqrt{R^2+1} \ln\left(\frac{1-P}{1-PR}\right)}{(R-1) \ln\left(\frac{2 - P(R+1-\sqrt{R^2+1})}{2 - P(R+1+\sqrt{R^2+1})}\right)} = 0.920$$ $$\Delta T_m = F \times LMTD_{cf} = 0.920 \times 79.05^\circ\text{C} = 72.73^\circ\text{C}$$ Step 4: Calculate the required heat transfer area: $$A = \dfrac{Q}{U \Delta T_m} = \dfrac{1,260,000\text{ W}}{450\text{ W/(m}^2\cdot\text{K)} \times 72.73\text{ K}} = \dfrac{1,260,000}{32,728} = 38.50\text{ m}^2$$ Distractor Analysis: - Option A (28.4 m²) uses the arithmetic temperature difference instead of LMTD. - Option B (35.4 m²) forgets the geometry correction factor $F$ (assuming ideal counterflow with $\Delta T_m = 79.05^\circ\text{C}$). - Option D (47.2 m²) assumes co-current flow configuration, which drastically lowers the temperature driving force.
Problem 2
A horizontal bare steel steam pipe (outside diameter $OD = 80.0\text{ mm}$, outer surface temperature $T_s = 150.0^\circ\text{C}$) traverses a large processing room where the quiescent air and enclosing room walls are at $T_\infty = T_{surr} = 25.0^\circ\text{C}$. The pipe surface has emissivity $\epsilon = 0.85$, and the natural convection heat transfer coefficient is $h = 8.50\text{ W}/(\text{m}^2\cdot\text{K})$. (Stefan-Boltzmann constant $\sigma = 5.67 \times 10^{-8}\text{ W}/(\text{m}^2\cdot\text{K}^4)$). The total combined heat loss per unit length of pipe ($q'_{total}$, in W/m) is most nearly:
- A267 W/m
- B385 W/m
- C560 W/mcorrect
- D715 W/m
Show the solution
Step 1: Calculate the outer surface area per unit length ($A'$) of the pipe: $$A' = \pi D = \pi (0.080\text{ m}) \approx 0.25133\text{ m}^2/\text{m}$$ Step 2: Calculate the convective heat loss per unit length ($q'_{conv}$): $$q'_{conv} = h A' (T_s - T_\infty) = (8.50\text{ W}/(\text{m}^2\cdot\text{K}))(0.25133\text{ m}^2/\text{m})(150.0^\circ\text{C} - 25.0^\circ\text{C})$$ $$q'_{conv} = (8.50)(0.25133)(125.0^\circ\text{C}) \approx 267.04\text{ W/m}$$ Step 3: Calculate the radiative heat loss per unit length ($q'_{rad}$): Convert temperatures to Kelvin: $$T_s = 150.0 + 273.15 = 423.15\text{ K}$$ $$T_{surr} = 25.0 + 273.15 = 298.15\text{ K}$$ $$T_s^4 = (423.15)^4 \approx 3.2057 \times 10^{10}\text{ K}^4$$ $$T_{surr}^4 = (298.15)^4 \approx 7.9009 \times 10^9\text{ K}^4 = 0.7901 \times 10^{10}\text{ K}^4$$ $$T_s^4 - T_{surr}^4 = (3.2057 - 0.7901) \times 10^{10} = 2.4156 \times 10^{10}\text{ K}^4$$ $$q'_{rad} = \epsilon \sigma A' (T_s^4 - T_{surr}^4)$$ $$q'_{rad} = (0.85)(5.67 \times 10^{-8}\text{ W}/(\text{m}^2\cdot\text{K}^4))(0.25133\text{ m}^2/\text{m})(2.4156 \times 10^{10}\text{ K}^4) \approx 292.64\text{ W/m}$$ Step 4: Compute the total combined heat loss rate ($q'_{total}$): $$q'_{total} = q'_{conv} + q'_{rad} = 267.04\text{ W/m} + 292.64\text{ W/m} = 559.68\text{ W/m} \approx 560\text{ W/m}$$ Distractor Analysis: - Option A (267 W/m): Accounts only for convective heat loss, omitting thermal radiation. - Option B (385 W/m): Uses temperatures in Celsius in the Stefan-Boltzmann equation. - Option C (560 W/m): Correct. - Option D (715 W/m): Assumes blackbody radiation ($\epsilon = 1.0$) with arithmetic error.
Problem 3
A counter-current double-pipe heat exchanger cools an organic process stream (mass flow rate $\dot{m}_h = 1.50\text{ kg/s}$, specific heat $c_{p,h} = 2.20\text{ kJ}/(\text{kg}\cdot\text{K})$) from $T_{h,in} = 120.0^\circ\text{C}$ to $T_{h,out} = 70.0^\circ\text{C}$ using cooling water entering at $T_{c,in} = 20.0^\circ\text{C}$ and exiting at $T_{c,out} = 50.0^\circ\text{C}$. The overall heat transfer coefficient is $U = 600.0\text{ W}/(\text{m}^2\cdot\text{K})$. In accordance with heat exchanger design relationships from the NCEES FE Reference Handbook ($q = \dot{m}_h c_{p,h} \Delta T_h = U A \Delta T_{lm}$), the total heat duty ($q$, in kW) and required heat transfer area ($A$, in $\text{m}^2$) are most nearly:
- A3.25 m², q = 115.0 kW
- B4.63 m², q = 165.0 kWcorrect
- C6.12 m², q = 210.0 kW
- D8.50 m², q = 280.0 kW
Show the solution
Step 1: Calculate the total heat transfer duty ($q$) from the hot fluid sensible cooling: $$q = \dot{m}_h c_{p,h} (T_{h,in} - T_{h,out}) = (1.50\text{ kg/s}) \times (2.20\text{ kJ}/(\text{kg}\cdot\text{K})) \times (120.0 - 70.0\text{ K})$$ $$q = (1.50) \times (2.20) \times (50.0) = 165.0\text{ kW} = 165,000\text{ W}$$ Step 2: Determine the terminal temperature differences and log mean temperature difference ($\Delta T_{lm}$) for counter-current flow: $$\Delta T_1 = T_{h,in} - T_{c,out} = 120.0^\circ\text{C} - 50.0^\circ\text{C} = 70.0^\circ\text{C}$$ $$\Delta T_2 = T_{h,out} - T_{c,in} = 70.0^\circ\text{C} - 20.0^\circ\text{C} = 50.0^\circ\text{C}$$ $$\Delta T_{lm} = \frac{\Delta T_1 - \Delta T_2}{\ln(\Delta T_1 / \Delta T_2)} = \frac{70.0 - 50.0}{\ln(70.0 / 50.0)} = \frac{20.0}{\ln(1.400)} = \frac{20.0}{0.33647} = 59.44^\circ\text{C}$$ Step 3: Solve for the required heat transfer surface area ($A$): $$A = \frac{q}{U \Delta T_{lm}} = \frac{165,000\text{ W}}{(600.0\text{ W}/(\text{m}^2\cdot\text{K})) \times (59.44\text{ K})} = \frac{165,000}{35,664} = 4.63\text{ m}^2$$ Distractor Analysis: - Option A: Uses arithmetic mean temperature difference instead of logarithmic mean. - Option B: Correct. - Option C: Uses parallel flow configuration temperature differences. - Option D: Inverts the terminal temperatures leading to smaller $\Delta T$.