A horizontal Venturi meter is installed in a pipeline carrying kerosene (density $\rho = 820\text{ kg/m}^3$) as shown in the diagram. The inlet pipe diameter is $D_1 = 150\text{ mm}$ and the throat diameter is $D_2 = 75\text{ mm}$. A differential mercury manometer ($\rho_m = 13,600\text{ kg/m}^3$) connected between the upstream inlet and the throat indicates a differential level of $h = 240\text{ mm}$. If the meter discharge coefficient is $C_d = 0.98$, the volumetric flow rate of kerosene is most nearly:
- A27.6 L/s
- B38.3 L/scorrect
- C45.1 L/s
- D52.8 L/s
Show the solution
Step 1: Calculate the differential pressure between the inlet and the throat from the manometer reading: $$\Delta P = P_1 - P_2 = (\rho_m - \rho) g h$$ $$\Delta P = (13,600 - 820)\text{ kg/m}^3 \times 9.81\text{ m/s}^2 \times 0.240\text{ m} = 12,780 \times 9.81 \times 0.240 = 30,089\text{ Pa} = 30.09\text{ kPa}$$ Step 2: Determine the diameter ratio and cross-sectional areas: $$\beta = \dfrac{D_2}{D_1} = \dfrac{75}{150} = 0.50$$ $$A_2 = \dfrac{\pi}{4} D_2^2 = \dfrac{\pi}{4} (0.075\text{ m})^2 = 4.4179 \times 10^{-3}\text{ m}^2$$ Step 3: Calculate the throat velocity using the Venturi equation from the FE Handbook: $$V_2 = \dfrac{C_d}{\sqrt{1 - \beta^4}} \sqrt{\dfrac{2 \Delta P}{\rho}} = \dfrac{0.98}{\sqrt{1 - 0.50^4}} \sqrt{\dfrac{2 \times 30,089}{820}}$$ $$\sqrt{1 - 0.0625} = \sqrt{0.9375} = 0.96825$$ $$V_2 = \dfrac{0.98}{0.96825} \times \sqrt{73.388} = 1.0121 \times 8.5667 = 8.670\text{ m/s}$$ Step 4: Compute the volumetric flow rate: $$Q = A_2 V_2 = 4.4179 \times 10^{-3}\text{ m}^2 \times 8.670\text{ m/s} = 0.03830\text{ m}^3/\text{s} = 38.3\text{ L/s}$$ Distractor Analysis: - Option A (27.6 L/s) forgets the mercury buoyant density correction, using $\rho_m$ instead of $(\rho_m - \rho)$, or inverts the diameter ratio. - Option C (45.1 L/s) omits the velocity-of-approach factor $\sqrt{1 - \beta^4}$ and assumes an ideal $C_d = 1.0$. - Option D (52.8 L/s) calculates the flow using the inlet area $A_1$ instead of the throat area $A_2$.