Problem 1
A stack releases a pollutant at a rate of 50 g/s into a wind blowing at 3 m/s. At a downwind distance where the horizontal and vertical dispersion coefficients are $\sigma_y = 50$ m and $\sigma_z = 30$ m, and the effective stack height is 40 m, use the Gaussian plume ground-level centerline equation $C = \dfrac{Q}{\pi u \sigma_y \sigma_z}\exp\left(-\dfrac{H^2}{2\sigma_z^2}\right)$ to find the ground-level concentration at that point.
- A3.537 mg/m³, omitting the exponential decay term entirely
- B1.454 mg/m³correct
- C0.785 mg/m³, using the stack height directly in the exponent instead of its square
- D2.908 mg/m³, omitting the factor of 2 in the denominator of the exponent
Show the solution
The Gaussian plume model splits the ground-level concentration into two parts: a pre-exponential term that would apply if the plume stayed at ground level, and an exponential penalty that accounts for how much of the plume's mass is still up at the effective stack height and hasn't yet dispersed down to the ground. Pre-exponential term: $\dfrac{Q}{\pi u \sigma_y \sigma_z} = \dfrac{50}{\pi(3)(50)(30)} = \dfrac{50}{14{,}137} = 0.003537$ g/m³. Exponential term: $\exp\left(-\dfrac{40^2}{2(30)^2}\right) = \exp\left(-\dfrac{1{,}600}{1{,}800}\right) = \exp(-0.8889) = 0.4111$. Ground-level concentration: $C = 0.003537 \times 0.4111 = 0.001454$ g/m³ $= 1.454$ mg/m³. Because the exponential term depends on the SQUARE of the stack height, a taller stack reduces ground-level concentration far more than proportionally — which is exactly the engineering principle behind using tall stacks to dilute emissions before they reach breathing-level air, though tall stacks alone don't reduce the total mass emitted and are not a substitute for actual emission control.
Problem 2
An electric utility generating station with an effective stack height of H = 120 m discharges sulfur dioxide (SO₂) at a continuous mass emission rate of Q = 180 g/s. Downwind at x = 2.0 km under neutral atmospheric stability (Pasquill-Gifford Class D with wind speed u = 5.0 m/s), lateral dispersion is σy = 140 m. A nocturnal subsidence inversion layer caps the mixing zone at an altitude of L = 160 m above ground level. After sunrise, solar ground heating creates a convective boundary layer that erodes the nocturnal inversion up to the base of the inversion lid (z = L), triggering complete vertical mixing and trapping (fumigation), as shown in the meteorological dispersion profile. Using the EPA fumigation formula C(x,0,0) = Q / [√(2π) · u · σy · L], what is the peak ground-level centerline SO₂ concentration?
- A229 µg/m³
- B412 µg/m³
- C641 µg/m³correct
- D855 µg/m³
Show the solution
1. METEOROLOGICAL FUMIGATION PHENOMENON: When an elevated plume is released just beneath a strong thermal subsidence inversion, nocturnal stable stratification prevents downward dispersion. After sunrise, solar ground warming creates intense convective thermal updrafts that rapidly mix the plume uniformly throughout the layer between ground level ($z = 0$) and the inversion base ($z = L = 160\text{ m}$). 2. MATHEMATICAL FUMIGATION TRAPPING FORMULATION: Under complete vertical mixing below height $L$, the vertical Gaussian distribution is replaced by the uniform density $1/L$: $$C_{\text{fum}}(x, 0, 0) = \frac{Q}{\sqrt{2\pi} \cdot u \cdot \sigma_y \cdot L}$$ Given: $$Q = 180.0\text{ g/s}$$ $$u = 5.00\text{ m/s}$$ $$\sigma_y = 140.0\text{ m}$$ $$L = 160.0\text{ m}$$ $$\sqrt{2\pi} = 2.50663$$ 3. CONCENTRATION CALCULATION: Denominator: $$\text{Denominator} = (2.50663) \times (5.00\text{ m/s}) \times (140.0\text{ m}) \times (160.0\text{ m}) = 280{,}742.6\text{ m}^3/\text{s}$$ Centerline ground-level concentration: $$C_{\text{fum}} = \frac{180.0\text{ g/s}}{280{,}742.6\text{ m}^3/\text{s}} = 6.41157 \times 10^{-4}\text{ g/m}^3$$ Convert to micrograms per cubic meter ($1\text{ g} = 10^6\text{ }\mu\text{g}$): $$C_{\text{fum}} = (6.41157 \times 10^{-4}) \times 10^6\text{ }\mu\text{g/m}^3 = 641.16\text{ }\mu\text{g/m}^3 \approx 641\text{ }\mu\text{g/m}^3$$ DISTRACTOR RATIONALE: - Option A (229 µg/m³) is unconstrained Gaussian dispersion without vertical trapping: $C = [Q / (\pi u \sigma_y \sigma_z)] \exp(-H^2 / 2\sigma_z^2) = 229\text{ }\mu\text{g/m}^3$ (using $\sigma_z = 65\text{ m}$). - Option B (412 µg/m³) erroneously substitutes $\pi$ for $\sqrt{2\pi}$ in the denominator. - Option D (855 µg/m³) mistakenly uses stack height $H = 120\text{ m}$ in place of the inversion lid height $L = 160\text{ m}$.
Problem 3
A Stairmand standard high-efficiency cyclone collector treats an industrial ventilation airstream: cyclone body diameter D = 0.80 m, rectangular tangential inlet height a = 0.40 m, and inlet width b = 0.16 m (inlet area Ai = 0.064 m²). The volumetric gas flow rate is Q = 1.152 m³/s at 20°C, and the effective number of spiral turns in the outer vortex is Ne = 5.0. Dynamic viscosity of air is µ = 1.81 × 10⁻⁵ Pa·s and particle density is ρp = 2,200 kg/m³ (gas density ρg is negligible). Based on the Stairmand cut-diameter equation d_pc = √[ 9·µ·b / (2·π·Ne·vi·(ρp - ρg)) ], determine the tangential inlet gas velocity vi, the 50% collection cut-diameter d_pc, and the collection efficiency for particles with aerodynamic diameter equal to twice the cut diameter (dp = 2·d_pc) using the Lapple fractional efficiency relationship η(dp) = (dp/d_pc)² / [1 + (dp/d_pc)²].
- AInlet velocity = 12.5 m/s (Cut-diameter d_pc = 6.85 µm, Collection efficiency at 2·d_pc = 65.0%)
- BInlet velocity = 24.0 m/s (Cut-diameter d_pc = 3.25 µm, Collection efficiency at 2·d_pc = 88.5%)
- CInlet velocity = 18.0 m/s (Cut-diameter d_pc = 4.58 µm, Collection efficiency at 2·d_pc = 80.0%)correct
- DInlet velocity = 15.0 m/s (Cut-diameter d_pc = 5.42 µm, Collection efficiency at 2·d_pc = 72.0%)
Show the solution
**Step 1: Compute tangential inlet gas velocity ($v_i$)** $$v_i = \frac{Q}{A_i} = \frac{1.152\text{ m}^3/\text{s}}{0.064\text{ m}^2} = 18.0\text{ m/s}$$ **Step 2: Calculate the 50% cut-diameter ($d_{pc}$) via Stairmand formulation** The Stairmand formula from the NCEES FE Reference Handbook is: $$d_{pc} = \sqrt{\frac{9 \, \mu \, b}{2 \pi \, N_e \, v_i \, (\rho_p - \rho_g)}}$$ Evaluate numerator: $$\text{Num} = 9 \times (1.81 \times 10^{-5}\text{ Pa}\cdot\text{s}) \times 0.16\text{ m} = 2.6064 \times 10^{-5}\text{ kg/s}$$ Evaluate denominator: $$\text{Den} = 2 \pi \times 5.0 \times 18.0\text{ m/s} \times (2{,}200 - 1.2)\text{ kg/m}^3 = 31.4159 \times 18.0 \times 2198.8 = 1{,}243{,}393$$ Calculate the quotient: $$\frac{\text{Num}}{\text{Den}} = \frac{2.6064 \times 10^{-5}}{1{,}243{,}393} = 2.0962 \times 10^{-11}\text{ m}^2$$ Take the square root: $$d_{pc} = \sqrt{2.0962 \times 10^{-11}} = 4.578 \times 10^{-6}\text{ m} = 4.58\,\mu\text{m}$$ **Step 3: Compute fractional collection efficiency at $d_p = 2 \cdot d_{pc}$** Using the Lapple empirical model: $$\eta(d_p) = \frac{(d_p / d_{pc})^2}{1 + (d_p / d_{pc})^2} = \frac{2^2}{1 + 2^2} = \frac{4}{5} = 0.800 = 80.0\%$$ **Distractor Rationale:** - Option A uses an incorrect inlet area $A_i = 0.092\text{ m}^2$, yielding $v_i = 12.5\text{ m/s}$. - Option B assumes a high inlet velocity of $24.0\text{ m/s}$. - Option D neglects the factor of $2\pi$ in the denominator, computing $d_{pc} = 5.42\,\mu\text{m}$.