Water and Wastewater on the FE Environmental exam

Water and Wastewater accounts for 13 of the 110 questions — 11.8% of your exam. It is one of the three heaviest areas on this paper, so it is worth your study time before almost anything else.

Questions13
Share of exam11.8%
Rank by weight2/15
In our bank44

What Water and Wastewater covers

On the FE Environmental exam this area covers water quality and demand, coagulation, flocculation and sedimentation, filtration, disinfection, primary and secondary wastewater treatment, activated sludge, and sludge handling.

What the questions look like: A detention time, an overflow or loading rate, a chemical dose, or a removal efficiency.

Worth knowing cold: Loading rates and detention times are the backbone of this area. Keep the units straight and most questions become one division.

3 free Water and Wastewater practice problems

These come from our FE Environmental bank, written to the same specification as the exam. Try each one before opening the solution.

Problem 1

An activated sludge aeration basin treats a flow of 4,000 m³/day, removing 250 mg/L of BOD. Using a simplified oxygen demand coefficient of 0.9 kg O₂ per kg of BOD removed to find the actual oxygen transfer rate (AOTR), and then a field correction factor of 1.6 (accounting for lower oxygen transfer efficiency in wastewater compared to clean water) to find the standard oxygen transfer rate (SOTR), what SOTR must the aeration system be designed to supply?

  1. A900 kg O₂/day, which is the AOTR before applying the field correction factor
  2. B1,440 kg O₂/daycorrect
  3. C2,250 kg O₂/day, applying the correction factor to the BOD load before computing AOTR instead of after
  4. D562.5 kg O₂/day, dividing by the correction factor instead of multiplying by it
Show the solution

This calculation has two distinct stages that must be kept in the right order: first find the actual oxygen demand of the biological process (AOTR), then inflate that figure to account for the fact that a real aeration device transfers oxygen into wastewater less efficiently than it would into clean water under standard test conditions — which is why aerators are rated in SOTR but must be selected to deliver enough SOTR to cover the AOTR the process actually needs. Mass of BOD removed per day: $4{,}000 \text{ m}^3/\text{day} \times 250 \text{ mg/L} = 1{,}000{,}000 \text{ g/day} = 1{,}000$ kg/day (since 1 mg/L over 1 m³ equals 1 gram). AOTR: $0.9 \times 1{,}000 = 900$ kg O₂/day. SOTR: $900 \times 1.6 = 1{,}440$ kg O₂/day. Specifying blowers and diffusers sized only to the AOTR (skipping the correction factor) would leave the plant chronically short of dissolved oxygen under actual field conditions, which shows up as poor treatment performance and, in the worst case, a failing effluent BOD.

Problem 2

A municipal wastewater treatment plant operates a secondary circular clarifier treating an influent flow of Qo = 18,000 m³/d (750 m³/h). The return activated sludge (RAS) recycle flow is maintained at Qr = 7,200 m³/d (300 m³/h, recycle ratio R = 0.40). The mixed liquor entering the center-feed well has a suspended solids concentration of X = 3,500 mg/L (3.50 kg/m³). The clarifier has an internal diameter of D = 28.0 m and a surface area of A = 615.75 m². Assuming complete solids capture (effluent suspended solids Xe ≈ 0) and steady-state mass balance, calculate the total Solids Loading Rate (SLR) applied to the clarifier floor in kg/(m²·h) and the theoretical underflow sludge concentration Xr in mg/L.

  1. ASLR = 4.26 kg/(m²·h); Xr = 8,750 mg/L
  2. BSLR = 5.97 kg/(m²·h); Xr = 12,250 mg/Lcorrect
  3. CSLR = 7.84 kg/(m²·h); Xr = 15,500 mg/L
  4. DSLR = 3.48 kg/(m²·h); Xr = 9,800 mg/L
Show the solution

1. TOTAL CLARIFIER INFLUENT FLOW (QT): The secondary clarifier receives both aeration basin discharge and recycle return flow: $$Q_T = Q_o + Q_r = 750\text{ m}^3/\text{h} + 300\text{ m}^3/\text{h} = 1{,}050\text{ m}^3/\text{h}$$ On a daily basis: $Q_T = 18{,}000 + 7{,}200 = 25{,}200\text{ m}^3/\text{d}$. 2. CLARIFIER SURFACE AREA (A): $$A = \frac{\pi D^2}{4} = \frac{\pi (28.0\text{ m})^2}{4} = 615.75\text{ m}^2$$ 3. SOLIDS LOADING RATE (SLR): Solids mass loading applied to the clarifier floor: $$\text{Solids mass rate} = Q_T \times X = 1{,}050\text{ m}^3/\text{h} \times 3.50\text{ kg/m}^3 = 3{,}675\text{ kg/h}$$ $$\text{SLR} = \frac{Q_T \times X}{A} = \frac{3{,}675\text{ kg/h}}{615.75\text{ m}^2} = 5.968\text{ kg/(m}^2\cdot\text{h)} \approx 5.97\text{ kg/(m}^2\cdot\text{h)}$$ 4. UNDERFLOW SLUDGE CONCENTRATION (Xr): From steady-state solids mass balance with complete solids capture ($X_e = 0$): $$(Q_o + Q_r) X = Q_r X_r$$ $$X_r = X \left( \frac{Q_o + Q_r}{Q_r} \right) = 3{,}500\text{ mg/L} \times \left( \frac{750 + 300}{300} \right) = 3{,}500 \times 3.50 = 12{,}250\text{ mg/L}$$ DISTRACTOR RATIONALE: - Option A (4.26 kg/(m²·h), 8,750 mg/L) computes solids loading based on influent flow $Q_o$ alone, ignoring RAS recycle. - Option C (7.84 kg/(m²·h), 15,500 mg/L) erroneously adds $Q_r$ twice or uses an undersized effective area. - Option D (3.48 kg/(m²·h), 9,800 mg/L) computes solids loading based only on underflow withdrawal.

Problem 3

A dissolved air flotation (DAF) unit thickens waste activated sludge (WAS) prior to anaerobic digestion. The influent sludge flow rate is Q = 1,200 m³/d (50.0 m³/h) with an influent total suspended solids concentration of Sa = 8,000 mg/L (8.0 kg/m³). Pilot testing establishes an optimum air-to-solids ratio of A/S = 0.030 kg air/kg TSS. The saturator operates at a gauge pressure of P = 450 kPa (absolute pressure P_abs = 551.3 kPa, pressure ratio P_abs/Patm = 5.44) with an air saturation efficiency of f = 85.0%. The solubility of air in water at 20°C and atmospheric pressure is sa = 22.44 mg air/L water (0.02244 kg/m³). Calculate the total daily dry solids load to be floated, the required pressurized recycle flow rate R, and the recycle ratio R/Q.

  1. ADaily solids mass = 7,200 kg/d (Recycle flow R = 2,450 m³/d, Recycle ratio R/Q = 2.04)
  2. BDaily solids mass = 9,600 kg/d (Recycle flow R = 3,540 m³/d, Recycle ratio R/Q = 2.95)correct
  3. CDaily solids mass = 12,000 kg/d (Recycle flow R = 4,820 m³/d, Recycle ratio R/Q = 4.02)
  4. DDaily solids mass = 8,400 kg/d (Recycle flow R = 1,980 m³/d, Recycle ratio R/Q = 1.65)
Show the solution

**Step 1: Compute total daily dry solids mass ($M_{solids}$)** $$M_{solids} = Q \times S_a = 1{,}200\text{ m}^3/\text{d} \times 8.0\text{ kg/m}^3 = 9{,}600\text{ kg TSS/day}$$ **Step 2: Calculate daily mass of air required ($M_{air}$)** Using target air-to-solids ratio $A/S = 0.030\text{ kg air/kg solids}$: $$M_{air} = (A/S) \times M_{solids} = 0.030 \times 9{,}600\text{ kg/d} = 288.0\text{ kg air/day}$$ **Step 3: Calculate dissolved air released per unit volume of recycle ($C_{air}$)** According to Henry's law for pressurized DAF recycle with saturation fraction $f = 0.85$: $$C_{air} = s_a \left( f \frac{P_{abs}}{P_{atm}} - 1 \right) = 22.44\text{ mg/L} \times \left( 0.85 \times 5.442 - 1 \right)$$ $$C_{air} = 22.44 \times (4.6257 - 1) = 22.44 \times 3.6257 = 81.36\text{ mg/L} = 0.08136\text{ kg air/m}^3$$ **Step 4: Determine the required recycle flow rate ($R$) and recycle ratio ($R/Q$)** $$R = \frac{M_{air}}{C_{air}} = \frac{288.0\text{ kg/day}}{0.08136\text{ kg/m}^3} = 3{,}539.8\text{ m}^3/\text{day} \approx 3{,}540\text{ m}^3/\text{d}$$ $$\frac{R}{Q} = \frac{3{,}539.8}{1{,}200} = 2.95 \quad (295\%)$$ **Distractor Rationale:** - Option A assumes a lower solids concentration of $6{,}000\text{ mg/L}$ ($M_{solids} = 7{,}200\text{ kg/d}$). - Option C neglects the saturation efficiency factor ($f = 1.0$), underestimating dissolved air concentration and inflating recycle requirements. - Option D uses gauge pressure directly in Henry's law ratio instead of absolute pressure.

Find out where you actually stand

A free 20-question diagnostic across every FE Environmental knowledge area, scored in the real exam interface. You get a projected score and the areas costing you the most — so you know whether Water and Wastewater is where your time should go at all.

Start the free Environmental diagnostic

Retaking the FE Environmental exam?

Copy the scores from your NCEES diagnostic report and see whether Water and Wastewater is where your next attempt gains the most points, or whether another area deserves the time first.

Analyze my diagnostic report

Other FE Environmental knowledge areas