Problem 1
A pump must deliver 0.08 m³/s through a 500 m long, 0.2 m diameter pipe (friction factor f = 0.02) to a tank 15 m higher in elevation, with minor losses totaling $\sum K = 5$. The pump's efficiency is 70%. Using $V = Q/A$, Darcy-Weisbach for friction loss, $h_{minor} = K\dfrac{V^2}{2g}$ for minor losses, and $P = \dfrac{\rho g Q H_{total}}{\eta}$, what pump power is required?
- A11.6 kW, omitting both the friction loss and the minor losses, using only the elevation lift
- B26.0 kW, omitting the pump efficiency (computing the hydraulic power delivered to the water, not the power the pump itself must draw)
- C37.2 kWcorrect
- D23.1 kW, omitting the minor losses while including friction loss and elevation
Show the solution
Total dynamic head is the sum of everything the pump must overcome — the static elevation lift plus every form of energy loss along the pipe — and skipping any one of those components (as three of the distractors each do) understates the head and therefore the power the pump actually needs to supply. Flow velocity: $V = \dfrac{Q}{A} = \dfrac{0.08}{\frac{\pi}{4}(0.2)^2} = \dfrac{0.08}{0.03142} = 2.546$ m/s. Friction loss: $h_f = f\dfrac{L}{D}\dfrac{V^2}{2g} = 0.02\dfrac{500}{0.2}\dfrac{(2.546)^2}{19.62} = 0.02(2{,}500)(0.3304) = 16.52$ m. Minor losses: $h_{minor} = 5\dfrac{(2.546)^2}{19.62} = 5(0.3304) = 1.65$ m. Total dynamic head: $15 + 16.52 + 1.65 = 33.18$ m. Hydraulic power: $\rho g Q H = 1{,}000(9.81)(0.08)(33.18) = 26{,}040$ W. Shaft power accounting for pump efficiency: $\dfrac{26{,}040}{0.70} = 37{,}200$ W $= 37.2$ kW. The gap between the hydraulic power (26.0 kW) and the shaft power (37.2 kW) is the energy lost to inefficiency inside the pump itself, which is why pump efficiency is a real operating cost, not a paperwork detail — a lower-efficiency pump selected on first cost alone draws more electricity for the entire life of the installation to move the exact same water.
Problem 2
A closed square loop pipe network ABCD delivers water through cast iron pipes. Pipe head losses follow the Darcy-Weisbach flow relationship hf = r·Q² (where r is pipe resistance in s²/m⁵, Q is discharge in m³/s, and clockwise flow is defined as positive): - Pipe AB: r₁ = 30.0 s²/m⁵, initial assumed flow Q₁ = +0.080 m³/s (CW) - Pipe BC: r₂ = 50.0 s²/m⁵, initial assumed flow Q₂ = +0.030 m³/s (CW) - Pipe CD: r₃ = 40.0 s²/m⁵, initial assumed flow Q₃ = -0.050 m³/s (CCW) - Pipe DA: r₄ = 60.0 s²/m⁵, initial assumed flow Q₄ = -0.040 m³/s (CCW) According to the Hardy Cross iterative loop head-loss correction formula: $$\Delta Q = -\frac{\sum h_f}{\sum 2 r |Q|}$$ calculate the algebraic sum of head losses around the loop (Σhf), the first-iteration flow correction ΔQ (in L/s), and the resulting corrected flow rate in Pipe AB (Q'AB in L/s).
- AΔQ = -5.40 L/s; Σhf = +0.0850 m; Q_AB = 74.6 L/s
- BΔQ = +2.47 L/s; Σhf = -0.0410 m; Q_AB = 82.5 L/s
- CΔQ = -2.47 L/s; Σhf = +0.0410 m; Q_AB = 77.5 L/scorrect
- DΔQ = -1.20 L/s; Σhf = +0.0205 m; Q_AB = 78.8 L/s
Show the solution
1. ALGEBRAIC SUM OF HEAD LOSSES (Σhf): Using the sign convention (clockwise positive, counter-clockwise negative): - Pipe AB: $h_{f,1} = +r_1 Q_1^2 = +30.0 \times (0.080)^2 = +30.0 \times 0.0064 = +0.1920\text{ m}$ - Pipe BC: $h_{f,2} = +r_2 Q_2^2 = +50.0 \times (0.030)^2 = +50.0 \times 0.0009 = +0.0450\text{ m}$ - Pipe CD: $h_{f,3} = -r_3 Q_3^2 = -40.0 \times (0.050)^2 = -40.0 \times 0.0025 = -0.1000\text{ m}$ - Pipe DA: $h_{f,4} = -r_4 Q_4^2 = -60.0 \times (0.040)^2 = -60.0 \times 0.0016 = -0.0960\text{ m}$ Sum of head losses around the closed loop: $$\sum h_f = +0.1920 + 0.0450 - 0.1000 - 0.0960 = +0.0410\text{ m}$$ (Because $\sum h_f > 0$, clockwise flow is carrying too much head loss, so the correction $\Delta Q$ must be negative). 2. DENOMINATOR COMPUTATION Σ(2 r |Q|): - Pipe AB: $2 r_1 |Q_1| = 2 \times 30.0 \times 0.080 = 4.80\text{ s/m}^2$ - Pipe BC: $2 r_2 |Q_2| = 2 \times 50.0 \times 0.030 = 3.00\text{ s/m}^2$ - Pipe CD: $2 r_3 |Q_3| = 2 \times 40.0 \times 0.050 = 4.00\text{ s/m}^2$ - Pipe DA: $2 r_4 |Q_4| = 2 \times 60.0 \times 0.040 = 4.80\text{ s/m}^2$ Sum of derivatives: $$\sum 2 r |Q| = 4.80 + 3.00 + 4.00 + 4.80 = 16.60\text{ s/m}^2$$ 3. HARDY CROSS FLOW CORRECTION (ΔQ): $$\Delta Q = -\frac{\sum h_f}{\sum 2 r |Q|} = -\frac{+0.0410\text{ m}}{16.60\text{ s/m}^2} = -0.0024699\text{ m}^3/\text{s} = -2.47\text{ L/s}$$ Corrected discharge in Pipe AB: $$Q'_{AB} = Q_1 + \Delta Q = 0.080 - 0.00247 = 0.07753\text{ m}^3/\text{s} = 77.53\text{ L/s} \approx 77.5\text{ L/s}$$ DISTRACTOR RATIONALE: - Option A (ΔQ = -5.40 L/s) neglects the factor of 2 in the denominator derivative ($n=1$ instead of $n=2$). - Option B (ΔQ = +2.47 L/s) drops the negative sign in the Hardy Cross formula, incorrectly increasing CW flow. - Option D (ΔQ = -1.20 L/s) double counts pipes or halves the closure error.
Problem 3
A water distribution booster station delivers water from Reservoir 1 (water surface elevation $z_1 = 120\text{ m}$) to Reservoir 2 ($z_2 = 165\text{ m}$) through an $800\text{-m}$ long commercial steel pipeline with an inside diameter of $D = 250\text{ mm}$ ($0.25\text{ m}$), as shown in the system profile. The design discharge is $Q = 0.080\text{ m}^3\text{/s}$, the Darcy-Weisbach friction factor is $f = 0.020$, and the sum of minor loss coefficients across valves, fittings, and transitions is $\sum K_L = 4.50$. In accordance with pipe network energy equations from the NCEES FE Reference Handbook ($H_p = \Delta z + h_f + h_m$), the total dynamic head $H_p$ that the booster pump must deliver to the water is most nearly:
- A54.3 mcorrect
- B45.0 m
- C63.8 m
- D72.5 m
Show the solution
Step 1: Compute pipe cross-sectional area and mean flow velocity: $$A = \frac{\pi}{4} D^2 = \frac{\pi}{4} (0.25\text{ m})^2 = 0.049087\text{ m}^2$$ $$V = \frac{Q}{A} = \frac{0.080\text{ m}^3\text{/s}}{0.049087\text{ m}^2} = 1.62975\text{ m/s}$$ Step 2: Determine the velocity head: $$\frac{V^2}{2g} = \frac{(1.62975\text{ m/s})^2}{2(9.81\text{ m/s}^2)} = \frac{2.65608}{19.62} = 0.135376\text{ m}$$ Step 3: Calculate major friction head loss and minor head losses: $$h_f = f \frac{L}{D} \frac{V^2}{2g} = 0.020 \times \left(\frac{800\text{ m}}{0.25\text{ m}}\right) \times 0.135376\text{ m} = 0.020 \times 3200 \times 0.135376\text{ m} = 8.6641\text{ m}$$ $$h_m = \sum K_L \frac{V^2}{2g} = 4.50 \times 0.135376\text{ m} = 0.6092\text{ m}$$ Total dynamic head loss: $h_L = h_f + h_m = 8.6641 + 0.6092 = 9.2733\text{ m}$. Step 4: Compute the total pump head required: $$\Delta z = z_2 - z_1 = 165.0\text{ m} - 120.0\text{ m} = 45.00\text{ m}$$ $$H_p = \Delta z + h_L = 45.00\text{ m} + 9.2733\text{ m} = 54.273\text{ m} \approx 54.3\text{ m}$$ Distractor Analysis: - Option A: Correct. - Option B: Omits all pipe friction and minor losses entirely, using static lift only: $45.0\text{ m}$. - Option C: Erroneously computes friction losses using a smaller nominal pipe diameter of $200\text{ mm}$, yielding $63.8\text{ m}$. - Option D: Doubles the equivalent pipe length or squares the minor loss coefficient: $72.5\text{ m}$.