Problem 1
A landfill cell is designed using a water balance approach to estimate leachate generation. The site receives 1,000 mm/year of precipitation, loses 600 mm/year to evapotranspiration, and 150 mm/year runs off the cover surface before infiltrating. The active cell area is 5 hectares. Using percolation $= P - ET - RO$, what volume of leachate is generated per year?
- A30,000 m³/year, subtracting only the evapotranspiration loss and ignoring runoff
- B50,000 m³/year, applying the full precipitation depth over the area without subtracting any losses
- C12,500 m³/yearcorrect
- D7,500 m³/year, subtracting evapotranspiration and runoff twice each
Show the solution
A landfill water balance treats the cover and waste mass like a watershed: of all the precipitation that falls, only the portion left over after evapotranspiration returns water to the atmosphere and surface runoff carries water away is left to actually infiltrate down through the waste and become leachate. Percolation depth: $P - ET - RO = 1{,}000 - 600 - 150 = 250$ mm/year. Converting to a volume over the 5-hectare area (1 hectare $= 10{,}000$ m², and 250 mm $= 0.25$ m): $0.25 \times (5 \times 10{,}000) = 0.25 \times 50{,}000 = 12{,}500$ m³/year. This leachate volume is what sizes the leachate collection and removal system (pipes, sumps, and the storage or treatment capacity needed), so underestimating it — for instance by skipping the runoff deduction, as in one of the distractors — would leave an undersized collection system that cannot keep up during wet years, risking a leachate mound building up against the landfill's bottom liner.
Problem 2
Under the Resource Conservation and Recovery Act (RCRA, 40 CFR Part 261 Subpart C), industrial solid wastes that are not specifically listed must be evaluated for four hazardous characteristics: Ignitability (D001), Corrosivity (D002), Reactivity (D003), and Toxicity (D004–D043). Match each industrial waste stream description to its official EPA RCRA regulatory hazardous characteristic waste code and threshold criteria.
Show the solution
1. IGNITABILITY (D001, 40 CFR § 261.21): Liquid wastes with a flash point $< 60^\circ\text{C}$ ($140^\circ\text{F}$) are classified as D001 ignitable hazardous waste. 2. CORROSIVITY (D002, 40 CFR § 261.22): Aqueous solutions with $\text{pH} \le 2.0$ or $\text{pH} \ge 12.5$ meet the D002 corrosivity criterion. 3. REACTIVITY (D003, 40 CFR § 261.23): Cyanide- or sulfide-bearing wastes releasing toxic gases between $\text{pH } 2.0$ and $11.5$ are D003 reactive wastes. 4. TOXICITY CHARACTERISTIC LEACHING PROCEDURE (TCLP - D008, 40 CFR § 261.24): Under Method 1311 TCLP, an extract lead concentration $\ge 5.0\text{ mg/L}$ defines D008 hazardous waste. DISTRACTORS: - F001 applies to listed spent solvent mixtures from non-specific sources (listed waste, not characteristic). - P-listed applies to acutely hazardous discarded commercial chemical products.
Problem 3
A municipal solid waste (MSW) sanitary landfill compliant with RCRA Subtitle D regulations covers an active footprint area of A = 100,000 m² (10.0 hectares). The base composite liner includes a compacted clay liner (CCL) of thickness L = 0.90 m (3.0 ft) with an in-situ hydraulic conductivity of K = 1.0 × 10⁻⁹ m/s. The leachate collection and removal system maintains an average leachate head of hL = 0.30 m on top of the liner. Assuming the base of the clay liner discharges freely into an atmospheric-pressure leak detection layer, use Darcy's law to calculate the vertical hydraulic gradient i, the Darcy flux (specific discharge q), the daily total potential leachate leakage rate Q_leak, and the annual leakage volume V_ann.
- ADarcy velocity q = 0.333 × 10⁻⁹ m/s (Daily leakage = 2.88 m³/d, Annual volume = 1,051 m³/yr)
- BDarcy velocity q = 1.333 × 10⁻⁹ m/s (Daily leakage = 11.52 m³/d, Annual volume = 4,205 m³/yr)correct
- CDarcy velocity q = 2.222 × 10⁻⁹ m/s (Daily leakage = 19.20 m³/d, Annual volume = 7,008 m³/yr)
- DDarcy velocity q = 0.864 × 10⁻⁹ m/s (Daily leakage = 7.46 m³/d, Annual volume = 2,723 m³/yr)
Show the solution
**Step 1: Calculate total hydraulic head difference ($Delta h$) and gradient ($i$)** Taking the base of the clay liner as the reference elevation datum ($z = 0$, $p = 0$): - Total head at top of liner: $h_{top} = z_{top} + h_L = 0.90\text{ m} + 0.30\text{ m} = 1.20\text{ m}$ - Total head at bottom of liner: $h_{bottom} = 0 + 0 = 0\text{ m}$ The total hydraulic head difference driving downward seepage is: $$\Delta h = h_{top} - h_{bottom} = 1.20\text{ m}$$ The hydraulic gradient across the clay thickness $L = 0.90\text{ m}$ is: $$i = \frac{\Delta h}{L} = \frac{1.20\text{ m}}{0.90\text{ m}} = 1.333$$ **Step 2: Calculate the Darcy flux (specific discharge $q$)** Applying Darcy's law: $$q = K \cdot i = 1.0 \times 10^{-9}\text{ m/s} \times 1.3333 = 1.333 \times 10^{-9}\text{ m/s}$$ **Step 3: Calculate daily volumetric leakage rate ($Q_{leak}$) and annual volume ($V_{ann}$)** For total area $A = 100{,}000\text{ m}^2$: $$Q_{leak} = q \times A = 1.3333 \times 10^{-9}\text{ m/s} \times 100{,}000\text{ m}^2 = 1.3333 \times 10^{-4}\text{ m}^3/\text{s}$$ Convert to daily volume ($86{,}400\text{ s/day}$): $$Q_{leak} = 1.3333 \times 10^{-4}\text{ m}^3/\text{s} \times 86{,}400\text{ s/d} = 11.52\text{ m}^3/\text{day} = 11{,}520\text{ L/day}$$ Annual leakage volume over 365 days: $$V_{ann} = 11.52\text{ m}^3/\text{d} \times 365\text{ d/yr} = 4{,}204.8\text{ m}^3/\text{year} \approx 4{,}205\text{ m}^3/\text{yr}$$ **Distractor Rationale:** - Option A erroneously calculates gradient as $i = h_L / L = 0.30 / 0.90 = 0.333$, completely ignoring the elevation head $L$ across the liner. - Option C takes an arbitrary double head $\Delta h = 2.0\text{ m}$. - Option D uses $K$ in m/day without accounting for seconds per day conversion, resulting in $7.46\text{ m}^3/\text{d}$.