FE Environmental · Knowledge area 14 of 15

Energy and Environment on the FE Environmental exam

Energy and Environment accounts for 4 of the 110 questions — 3.6% of your exam. It is one of the lighter areas, which makes it a good place to secure quick marks rather than a place to spend weeks.

Questions4
Share of exam3.6%
Rank by weight14/15
In our bank14

What Energy and Environment covers

On the FE Environmental exam this area covers energy sources and conversion, efficiency, emissions from energy use, renewable energy, life-cycle assessment, and sustainability metrics.

What the questions look like: An efficiency or emissions computation, or a comparison between energy options.

Worth knowing cold: Unit conversions between energy, power and emissions carry most of the difficulty here.

3 free Energy and Environment practice problems

These come from our FE Environmental bank, written to the same specification as the exam. Try each one before opening the solution.

Problem 1

A thermal power generation station generates a net electrical output of $600\text{ MW}$ with an overall thermodynamic thermal efficiency of $\eta_{\text{th}} = 38.0\%$. The balance of the thermal energy is rejected as waste heat to an evaporative wet cooling tower system. If the cooling tower dissipates $75.0\%$ of the plant's total rejected waste heat through latent heat of evaporation of water ($h_{fg} = 2{,}430\text{ kJ/kg} = 2.43 \times 10^6\text{ J/kg}$), what is the continuous evaporative water consumption rate (in kg/s)?

  1. A185 kg/s, assuming 100% of rejected heat is dissipated solely by sensible convective heat transfer
  2. B550 kg/s, calculating evaporation from total fuel input heat instead of rejected waste heat
  3. C403 kg/s, assuming 100% of rejected waste heat evaporates water instead of 75%
  4. D302 kg/scorrect
Show the solution

The energy-water nexus in power generation couples thermal thermodynamics with environmental water resource consumption. Step 1: Overall thermal efficiency relates useful electrical power output ($W_{\text{net}}$) to total fuel thermal heat input ($Q_{\text{in}}$): $\eta_{\text{th}} = \dfrac{W_{\text{net}}}{Q_{\text{in}}} \implies Q_{\text{in}} = \dfrac{600\text{ MW}}{0.380} = 1{,}578.95\text{ MW}$. Step 2: By the First Law of Thermodynamics, rejected waste heat is: $Q_{\text{waste}} = Q_{\text{in}} - W_{\text{net}} = 1{,}578.95 - 600 = 978.95\text{ MW} = 9.7895 \times 10^8\text{ J/s}$. Step 3: The evaporative cooling tower transfers $75.0\%$ of this rejected heat into latent heat of phase change: $Q_{\text{evap}} = 0.75 \times 9.7895 \times 10^8\text{ J/s} = 7.3421 \times 10^8\text{ J/s}$. Step 4: Evaporative mass loss rate using latent heat of vaporization ($h_{fg} = 2.43 \times 10^6\text{ J/kg}$): $\dot{m}_{\text{evap}} = \dfrac{Q_{\text{evap}}}{h_{fg}} = \dfrac{7.3421 \times 10^8\text{ J/s}}{2.43 \times 10^6\text{ J/kg}} = 302.14\text{ kg/s} \approx 302\text{ kg/s}$. This equates to roughly $1{,}088\text{ m}^3/\text{hr}$ of consumptive freshwater loss.

Problem 2

A 10.0-MW(DC) utility-scale solar photovoltaic power generation facility operates in the arid southwest with an annual capacity factor of CF = 24.0% (generating electricity 8,760 hours/year). The regional marginal electrical grid fuel mix that this solar plant displaces produces greenhouse gas emissions at a marginal rate of EFgrid = 0.650 kg CO₂e per kWh of electricity generated. Life-cycle emissions from solar module manufacture, transportation, and maintenance account for EFsolar = 0.040 kg CO₂e per kWh. Calculate the net annual avoided greenhouse gas emissions in metric tonnes of CO₂e per year (tonnes CO₂e/yr). Enter your calculated value to the nearest whole integer.

Show the solution

1. ANNUAL ELECTRICITY GENERATION: Given: - Peak capacity $P = 10.0\text{ MW} = 10{,}000\text{ kW}$ - Capacity factor $CF = 0.240$ - Operating hours per year $= 8{,}760\text{ h/yr}$ Annual electricity delivered: $$E_{\text{annual}} = 10{,}000\text{ kW} \times 8{,}760\text{ h/yr} \times 0.240 = 21{,}024{,}000\text{ kWh/yr}$$ 2. NET AVOIDED EMISSION FACTOR: $$\Delta EF = EF_{\text{grid}} - EF_{\text{solar}} = 0.650 - 0.040 = 0.610\text{ kg CO}_2\text{e/kWh}$$ 3. TOTAL ANNUAL AVOIDED GHG EMISSIONS: $$\text{Avoided GHG} = \frac{21{,}024{,}000\text{ kWh/yr} \times 0.610\text{ kg CO}_2\text{e/kWh}}{1{,}000\text{ kg/metric tonne}}$$ $$\text{Avoided GHG} = \frac{12{,}824{,}640\text{ kg/yr}}{1{,}000} = 12{,}824.64\text{ tonnes CO}_2\text{e/yr} \approx 12{,}825\text{ tonnes/yr}$$

Problem 3

An autonomous, off-grid air quality and meteorological monitoring station operates continuously with a steady electrical power consumption of P_load = 60 W at a nominal system DC bus voltage of V = 24 V. The station design location receives a design solar irradiation of PSH = 4.0 peak sun hours/day during the critical winter design month. The balance-of-system efficiency (accounting for dust soiling, temperature derating, wire resistance, and maximum power point tracking charge controller losses) is η_sys = 75.0%. The station battery bank requires N = 4 days of continuous autonomy without solar recharge, with a maximum allowable battery depth of discharge of DOD = 50% and a round-trip battery coulombic efficiency of η_batt = 85.0%. Determine the required PV solar array rated peak power (Wp) and the minimum battery bank storage capacity in Ampere-hours (Ah).

  1. ARequired PV array = 360 Wp (Battery storage capacity = 380 Ah)
  2. BRequired PV array = 620 Wp (Battery storage capacity = 720 Ah)
  3. CRequired PV array = 480 Wp (Battery storage capacity = 565 Ah)correct
  4. DRequired PV array = 540 Wp (Battery storage capacity = 440 Ah)
Show the solution

**Step 1: Compute daily energy consumption ($E_{daily}$)** The continuous 24-hour electrical load is: $$E_{daily} = P_{load} \times 24\text{ h/day} = 60\text{ W} \times 24\text{ h/d} = 1{,}440\text{ Wh/day}$$ **Step 2: Calculate the required PV solar array peak wattage rating ($P_{pv}$)** Taking into account available peak sun hours ($PSH = 4.0\text{ h/day}$) and total system efficiency ($eta_{sys} = 0.75$): $$P_{pv} = \frac{E_{daily}}{PSH \times \eta_{sys}} = \frac{1{,}440\text{ Wh/day}}{4.0\text{ h/day} \times 0.75} = \frac{1{,}440}{3.0} = 480\text{ W}_p$$ **Step 3: Calculate required battery storage capacity ($C_{batt}$) in Ampere-hours** For $N = 4\text{ days}$ of autonomy, depth of discharge $DOD = 0.50$, and battery efficiency $\eta_{batt} = 0.85$: $$\text{Total stored reserve energy} = \frac{E_{daily} \times N}{DOD \times \eta_{batt}} = \frac{1{,}440\text{ Wh/d} \times 4\text{ d}}{0.50 \times 0.85} = \frac{5{,}760\text{ Wh}}{0.425} = 13{,}553\text{ Wh}$$ Convert to Ampere-hours at system voltage $V_{bus} = 24\text{ V}$: $$C_{batt} = \frac{13{,}553\text{ Wh}}{24\text{ V}} = 564.7\text{ Ah} \approx 565\text{ Ah}$$ **Distractor Rationale:** - Option A neglects balance-of-system efficiency ($eta_{sys} = 1.0$), calculating $P_{pv} = 360\text{ W}_p$. - Option B assumes 80% DOD and 12V bus voltage instead of 24V. - Option D forgets the battery round-trip efficiency ($eta_{batt} = 1.0$), calculating $C_{batt} = 5760 / (0.50 \times 24) = 480\text{ Ah}$.

Find out where you actually stand

A free 20-question diagnostic across every FE Environmental knowledge area, scored in the real exam interface. You get a projected score and the areas costing you the most — so you know whether Energy and Environment is where your time should go at all.

Start the free Environmental diagnostic

Retaking the FE Environmental exam?

Copy the scores from your NCEES diagnostic report and see whether Energy and Environment is where your next attempt gains the most points, or whether another area deserves the time first.

Analyze my diagnostic report