Problem 1
A thermal power generation station generates a net electrical output of $600\text{ MW}$ with an overall thermodynamic thermal efficiency of $\eta_{\text{th}} = 38.0\%$. The balance of the thermal energy is rejected as waste heat to an evaporative wet cooling tower system. If the cooling tower dissipates $75.0\%$ of the plant's total rejected waste heat through latent heat of evaporation of water ($h_{fg} = 2{,}430\text{ kJ/kg} = 2.43 \times 10^6\text{ J/kg}$), what is the continuous evaporative water consumption rate (in kg/s)?
- A185 kg/s, assuming 100% of rejected heat is dissipated solely by sensible convective heat transfer
- B550 kg/s, calculating evaporation from total fuel input heat instead of rejected waste heat
- C403 kg/s, assuming 100% of rejected waste heat evaporates water instead of 75%
- D302 kg/scorrect
Show the solution
The energy-water nexus in power generation couples thermal thermodynamics with environmental water resource consumption. Step 1: Overall thermal efficiency relates useful electrical power output ($W_{\text{net}}$) to total fuel thermal heat input ($Q_{\text{in}}$): $\eta_{\text{th}} = \dfrac{W_{\text{net}}}{Q_{\text{in}}} \implies Q_{\text{in}} = \dfrac{600\text{ MW}}{0.380} = 1{,}578.95\text{ MW}$. Step 2: By the First Law of Thermodynamics, rejected waste heat is: $Q_{\text{waste}} = Q_{\text{in}} - W_{\text{net}} = 1{,}578.95 - 600 = 978.95\text{ MW} = 9.7895 \times 10^8\text{ J/s}$. Step 3: The evaporative cooling tower transfers $75.0\%$ of this rejected heat into latent heat of phase change: $Q_{\text{evap}} = 0.75 \times 9.7895 \times 10^8\text{ J/s} = 7.3421 \times 10^8\text{ J/s}$. Step 4: Evaporative mass loss rate using latent heat of vaporization ($h_{fg} = 2.43 \times 10^6\text{ J/kg}$): $\dot{m}_{\text{evap}} = \dfrac{Q_{\text{evap}}}{h_{fg}} = \dfrac{7.3421 \times 10^8\text{ J/s}}{2.43 \times 10^6\text{ J/kg}} = 302.14\text{ kg/s} \approx 302\text{ kg/s}$. This equates to roughly $1{,}088\text{ m}^3/\text{hr}$ of consumptive freshwater loss.
Problem 2
A 10.0-MW(DC) utility-scale solar photovoltaic power generation facility operates in the arid southwest with an annual capacity factor of CF = 24.0% (generating electricity 8,760 hours/year). The regional marginal electrical grid fuel mix that this solar plant displaces produces greenhouse gas emissions at a marginal rate of EFgrid = 0.650 kg CO₂e per kWh of electricity generated. Life-cycle emissions from solar module manufacture, transportation, and maintenance account for EFsolar = 0.040 kg CO₂e per kWh. Calculate the net annual avoided greenhouse gas emissions in metric tonnes of CO₂e per year (tonnes CO₂e/yr). Enter your calculated value to the nearest whole integer.
Show the solution
1. ANNUAL ELECTRICITY GENERATION: Given: - Peak capacity $P = 10.0\text{ MW} = 10{,}000\text{ kW}$ - Capacity factor $CF = 0.240$ - Operating hours per year $= 8{,}760\text{ h/yr}$ Annual electricity delivered: $$E_{\text{annual}} = 10{,}000\text{ kW} \times 8{,}760\text{ h/yr} \times 0.240 = 21{,}024{,}000\text{ kWh/yr}$$ 2. NET AVOIDED EMISSION FACTOR: $$\Delta EF = EF_{\text{grid}} - EF_{\text{solar}} = 0.650 - 0.040 = 0.610\text{ kg CO}_2\text{e/kWh}$$ 3. TOTAL ANNUAL AVOIDED GHG EMISSIONS: $$\text{Avoided GHG} = \frac{21{,}024{,}000\text{ kWh/yr} \times 0.610\text{ kg CO}_2\text{e/kWh}}{1{,}000\text{ kg/metric tonne}}$$ $$\text{Avoided GHG} = \frac{12{,}824{,}640\text{ kg/yr}}{1{,}000} = 12{,}824.64\text{ tonnes CO}_2\text{e/yr} \approx 12{,}825\text{ tonnes/yr}$$
Problem 3
An autonomous, off-grid air quality and meteorological monitoring station operates continuously with a steady electrical power consumption of P_load = 60 W at a nominal system DC bus voltage of V = 24 V. The station design location receives a design solar irradiation of PSH = 4.0 peak sun hours/day during the critical winter design month. The balance-of-system efficiency (accounting for dust soiling, temperature derating, wire resistance, and maximum power point tracking charge controller losses) is η_sys = 75.0%. The station battery bank requires N = 4 days of continuous autonomy without solar recharge, with a maximum allowable battery depth of discharge of DOD = 50% and a round-trip battery coulombic efficiency of η_batt = 85.0%. Determine the required PV solar array rated peak power (Wp) and the minimum battery bank storage capacity in Ampere-hours (Ah).
- ARequired PV array = 360 Wp (Battery storage capacity = 380 Ah)
- BRequired PV array = 620 Wp (Battery storage capacity = 720 Ah)
- CRequired PV array = 480 Wp (Battery storage capacity = 565 Ah)correct
- DRequired PV array = 540 Wp (Battery storage capacity = 440 Ah)
Show the solution
**Step 1: Compute daily energy consumption ($E_{daily}$)** The continuous 24-hour electrical load is: $$E_{daily} = P_{load} \times 24\text{ h/day} = 60\text{ W} \times 24\text{ h/d} = 1{,}440\text{ Wh/day}$$ **Step 2: Calculate the required PV solar array peak wattage rating ($P_{pv}$)** Taking into account available peak sun hours ($PSH = 4.0\text{ h/day}$) and total system efficiency ($eta_{sys} = 0.75$): $$P_{pv} = \frac{E_{daily}}{PSH \times \eta_{sys}} = \frac{1{,}440\text{ Wh/day}}{4.0\text{ h/day} \times 0.75} = \frac{1{,}440}{3.0} = 480\text{ W}_p$$ **Step 3: Calculate required battery storage capacity ($C_{batt}$) in Ampere-hours** For $N = 4\text{ days}$ of autonomy, depth of discharge $DOD = 0.50$, and battery efficiency $\eta_{batt} = 0.85$: $$\text{Total stored reserve energy} = \frac{E_{daily} \times N}{DOD \times \eta_{batt}} = \frac{1{,}440\text{ Wh/d} \times 4\text{ d}}{0.50 \times 0.85} = \frac{5{,}760\text{ Wh}}{0.425} = 13{,}553\text{ Wh}$$ Convert to Ampere-hours at system voltage $V_{bus} = 24\text{ V}$: $$C_{batt} = \frac{13{,}553\text{ Wh}}{24\text{ V}} = 564.7\text{ Ah} \approx 565\text{ Ah}$$ **Distractor Rationale:** - Option A neglects balance-of-system efficiency ($eta_{sys} = 1.0$), calculating $P_{pv} = 360\text{ W}_p$. - Option B assumes 80% DOD and 12V bus voltage instead of 24V. - Option D forgets the battery round-trip efficiency ($eta_{batt} = 1.0$), calculating $C_{batt} = 5760 / (0.50 \times 24) = 480\text{ Ah}$.