A pressure transducer outputs a signal that varies linearly from 0 to 5 V as pressure varies from 0 to 200 kPa. What pressure, in kPa, corresponds to an output of 3.2 V? Enter a number only.
Show the solution
A linear sensor maps its input and output ranges proportionally: both start at zero here, so the relationship is a simple ratio rather than requiring a slope-and-intercept line fit. pressure / 200 kPa = output / 5 V pressure = 200 (3.2 / 5.0) = 200 (0.64) = 128 kPa Equivalently, the sensor sensitivity is 5 V / 200 kPa = 0.025 V/kPa, so pressure = voltage / sensitivity = 3.2 / 0.025 = 128 kPa -- same number, useful to know both routes because some problems give you the sensitivity directly instead of the two full-scale endpoints. A linear calibration like this is an idealization real transducers only approximate; an actual device would come with a calibration curve or a stated nonlinearity error, but for the purposes of a problem that states the relationship IS linear, treating output and input as directly proportional is exactly what the stated assumption calls for.