Problem 1
An ideal gas occupies 2.0 m^3 at 300 kPa and 350 K. It is compressed at constant temperature to a pressure of 750 kPa. What is the resulting volume, in m^3? Enter a number only.
Show the solution
Constant temperature means this is governed by Boyle Law, which holds for an ideal gas at fixed T regardless of what the temperature value actually is -- 350 K never enters the calculation, it is only there to establish that the process is isothermal. p_1 V_1 = p_2 V_2 (300 kPa)(2.0 m^3) = (750 kPa)(V_2) V_2 = 600 / 750 = 0.8 m^3 The volume shrank to 0.8 m^3, a reduction to 40% of the original 2.0 m^3, consistent with the pressure having risen by a factor of 2.5 (300 to 750) -- pressure and volume move in inverse proportion at fixed temperature, so a 2.5x pressure increase means a volume of 2.0/2.5 = 0.8 m^3, which matches and is a fast way to sanity-check the arithmetic without redoing it from scratch.
Problem 2
An ideal vapor-compression refrigeration cycle operating with refrigerant R-134a circulates mass flow rate $\dot{m} = 0.0800\text{ kg/s}$. Saturated vapor enters the compressor at evaporator temperature $T_{evap} = -10.0^\circ\text{C}$ ($h_1 = 244.5\text{ kJ/kg}$, $s_1 = 0.9377\text{ kJ}/(\text{kg}\cdot\text{K})$). Isentropic compression to condenser pressure $P_{cond} = 1.00\text{ MPa}$ ($10.0\text{ bar}$) yields superheated vapor at $h_2 = 282.5\text{ kJ/kg}$. Saturated liquid leaves the condenser at $1.00\text{ MPa}$ with $h_3 = 107.3\text{ kJ/kg}$ and expands isenthalpically through a throttle valve ($h_4 = h_3$). In accordance with refrigeration cycle relationships from the NCEES FE Reference Handbook ($q_{in} = h_1 - h_4$, $w_c = h_2 - h_1$, $COP_R = q_{in}/w_c$), the coefficient of performance ($COP_R$) and cooling capacity ($\dot{Q}_{in}$, in kW) are most nearly:
- A2.45, Q_in = 7.45 kW
- B3.61, Q_in = 10.98 kWcorrect
- C4.82, Q_in = 14.65 kW
- D5.50, Q_in = 16.72 kW
Show the solution
Step 1: Calculate specific refrigeration capacity ($q_{in}$) and cooling load ($\dot{Q}_{in}$): $$q_{in} = h_1 - h_4 = 244.5\text{ kJ/kg} - 107.3\text{ kJ/kg} = 137.2\text{ kJ/kg}$$ $$\dot{Q}_{in} = \dot{m} q_{in} = (0.0800\text{ kg/s}) \times (137.2\text{ kJ/kg}) = 10.976\text{ kW} = 10.98\text{ kW}$$ Step 2: Calculate specific compressor work ($w_c$) and compressor power input ($\dot{W}_c$): $$w_c = h_2 - h_1 = 282.5\text{ kJ/kg} - 244.5\text{ kJ/kg} = 38.0\text{ kJ/kg}$$ $$\dot{W}_c = \dot{m} w_c = (0.0800\text{ kg/s}) \times (38.0\text{ kJ/kg}) = 3.040\text{ kW}$$ Step 3: Determine the coefficient of performance ($COP_R$): $$COP_R = \frac{q_{in}}{w_c} = \frac{137.2\text{ kJ/kg}}{38.0\text{ kJ/kg}} = 3.6105 = 3.61$$ Distractor Analysis: - Option A: Uses heat pump coefficient or assumes compressor isentropic efficiency $\eta = 0.70$. - Option B: Correct. - Option C: Uses Carnot cycle efficiency between evaporator and condenser temperatures. - Option D: Neglects enthalpy of liquid entering throttle valve.
Problem 3
An ideal regenerative Brayton gas turbine cycle operates with air ($c_p = 1.005\text{ kJ}/(\text{kg}\cdot\text{K})$, $k = 1.40$) between pressure limits of $100.0\text{ kPa}$ and $800.0\text{ kPa}$ (pressure ratio $r_p = 8.00$). Ambient air enters the compressor at $T_1 = 300.0\text{ K}$, and gases enter the turbine at $T_3 = 1300.0\text{ K}$. The regenerator has thermal effectiveness $\epsilon_{reg} = 0.750$. In accordance with air-standard regenerative Brayton cycle formulas from the NCEES FE Reference Handbook ($T_2 = T_1 r_p^{(k-1)/k}$, $T_4 = T_3 / r_p^{(k-1)/k}$, $T_x = T_2 + \epsilon_{reg}(T_4 - T_2)$, $\eta_{th} = \frac{w_{net}}{q_{in}}$), the thermal efficiency of the cycle ($\eta_{th}$) is most nearly:
- A44.8%
- B54.1%correct
- C62.5%
- D71.0%
Show the solution
Step 1: Compute isentropic temperatures after compression ($T_2$) and expansion ($T_4$): $$\frac{k - 1}{k} = \frac{1.40 - 1.00}{1.40} = 0.285714$$ $$r_p^{(k-1)/k} = (8.00)^{0.285714} = 1.811447$$ $$T_2 = T_1 r_p^{(k-1)/k} = (300.0\text{ K}) \times (1.811447) = 543.434\text{ K}$$ $$T_4 = \frac{T_3}{r_p^{(k-1)/k}} = \frac{1300.0\text{ K}}{1.811447} = 717.658\text{ K}$$ Step 2: Determine preheated temperature entering combustor ($T_x$) via regenerator effectiveness: $$T_x = T_2 + \epsilon_{reg} (T_4 - T_2) = 543.434 + (0.750)(717.658 - 543.434)$$ $$T_x = 543.434 + (0.750)(174.224\text{ K}) = 543.434 + 130.668 = 674.102\text{ K}$$ Step 3: Calculate work outputs, heat addition, and thermal efficiency ($\eta_{th}$): $$w_t = c_p (T_3 - T_4) = (1.005)(1300.0 - 717.658) = (1.005)(582.342) = 585.254\text{ kJ/kg}$$ $$w_c = c_p (T_2 - T_1) = (1.005)(543.434 - 300.0) = (1.005)(243.434) = 244.651\text{ kJ/kg}$$ $$w_{net} = w_t - w_c = 585.254 - 244.651 = 340.603\text{ kJ/kg}$$ $$q_{in} = c_p (T_3 - T_x) = (1.005)(1300.0 - 674.102) = (1.005)(625.898) = 629.027\text{ kJ/kg}$$ $$\eta_{th} = \frac{w_{net}}{q_{in}} = \frac{340.603\text{ kJ/kg}}{629.027\text{ kJ/kg}} = 0.541476 = 54.15\% = 54.1\%$$ Distractor Analysis: - Option A: Evaluates standard Brayton cycle without regenerator ($\eta = 1 - 1/r_p^{0.286} = 44.8\%$). - Option B: Correct. - Option C: Uses ideal regenerator with $\epsilon = 1.00$ ($\eta = 58.2\%$). - Option D: Uses Carnot efficiency between $1300\text{ K}$ and $300\text{ K}$ ($76.9\%$).