Problem 1
A municipal eco-district uses a closed-loop geothermal groundwater heat pump to provide heating to a civic center. The groundwater source maintains a constant evaporator temperature of $T_{\text{cold}} = 12.0^\circ\text{C}$ ($285.15\text{ K}$), while the building distribution hydronic system requires a condenser supply temperature of $T_{\text{hot}} = 38.0^\circ\text{C}$ ($311.15\text{ K}$). The building design thermal heating demand is $\dot{Q}_H = 150.0\text{ kW}$. If the actual heat pump achieves an overall Coefficient of Performance (COP) equal to $45.0\%$ of the theoretical Carnot maximum heating COP, what electrical power input $W_{\text{in}}$ (in kW) is required to drive the compressor?
- A12.5 kW, assuming an ideal Carnot heat pump without thermodynamic irreversibilities
- B67.5 kW, multiplying heating load directly by the 45% efficiency factor
- C122.2 kW, reporting the heat absorbed from the geothermal groundwater source
- D27.9 kWcorrect
Show the solution
A heat pump delivers thermal heat to a conditioned space by absorbing low-temperature heat from an environmental reservoir (groundwater) and consuming mechanical/electrical work. Step 1: Maximum theoretical Carnot Coefficient of Performance for heating: $\text{COP}_{\text{Carnot, heat}} = \dfrac{T_{\text{hot}}}{T_{\text{hot}} - T_{\text{cold}}} = \dfrac{311.15\text{ K}}{311.15 - 285.15\text{ K}} = \dfrac{311.15}{26.0\text{ K}} = 11.967$. Step 2: Actual operating heating COP accounting for motor, compressor, and heat exchanger irreversibilities: $\text{COP}_{\text{actual}} = 0.450 \times \text{COP}_{\text{Carnot}} = 0.450 \times 11.967 = 5.385$. Step 3: By definition, $\text{COP} = \dfrac{\dot{Q}_H}{W_{\text{in}}}$, where $\dot{Q}_H$ is thermal heat delivered and $W_{\text{in}}$ is electrical work input. Solving for electrical input power: $W_{\text{in}} = \dfrac{\dot{Q}_H}{\text{COP}_{\text{actual}}} = \dfrac{150.0\text{ kW}}{5.385} = 27.854\text{ kW} \approx 27.9\text{ kW}$. Step 4: The thermal energy extracted cleanly from the groundwater is $\dot{Q}_C = \dot{Q}_H - W_{\text{in}} = 150.0 - 27.9 = 122.1\text{ kW}$, saving massive grid power compared to electric resistance heating.
Problem 2
A wet limestone Flue Gas Desulfurization (FGD) spray absorber treats hot, dry combustion gas exiting an industrial boiler. The gas enters the absorber tower at a dry-bulb temperature of T₁ = 160°C with an initial humidity ratio of ω₁ = 0.020 kg H₂O/kg dry gas. In the scrubber, the flue gas undergoes adiabatic saturation by evaporating recirculating slurry water, exiting at its adiabatic saturation (wet-bulb) temperature of Twb = 55°C under complete saturation (100% relative humidity, ϕ = 1.0). The total atmospheric pressure in the scrubber is P = 101.325 kPa. At 55°C, the saturation vapor pressure of water is Pws = 15.76 kPa. If the dry flue gas mass flow rate is m_dry = 50.0 kg/s, calculate the increase in humidity ratio Δω and the required continuous water make-up rate V̇w in L/min (assuming water density ρw = 1,000 kg/m³).
- AΔω = 0.045 kg/kg; V̇w = 135 L/min
- BΔω = 0.142 kg/kg; V̇w = 426 L/min
- CΔω = 0.068 kg/kg; V̇w = 204 L/min
- DΔω = 0.095 kg/kg; V̇w = 284 L/mincorrect
Show the solution
1. EXIT SATURATION HUMIDITY RATIO (ω2): At $T_{wb} = 55^\circ\text{C}$ and $P_{ws} = 15.76\text{ kPa}$: $$\omega_2 = 0.622 \frac{P_{ws}}{P - P_{ws}} = 0.622 \times \frac{15.76\text{ kPa}}{101.325 - 15.76\text{ kPa}} = 0.622 \times \frac{15.76}{85.565} = 0.11456\text{ kg }H_2O/\text{kg dry gas}$$ 2. HUMIDITY RATIO INCREASE (Δω): $$\Delta \omega = \omega_2 - \omega_1 = 0.11456 - 0.02000 = 0.09456\text{ kg/kg} \approx 0.095\text{ kg/kg}$$ 3. WATER MAKE-UP EVAPORATION RATE (V̇w): Mass flow rate of evaporated water: $$\dot{m}_w = \dot{m}_{\text{dry}} \times \Delta \omega = 50.0\text{ kg/s} \times 0.09456\text{ kg/kg} = 4.728\text{ kg/s}$$ Volumetric water rate: $$\dot{V}_w = 4.728\text{ kg/s} \times \frac{1\text{ L}}{1.0\text{ kg}} \times 60\text{ s/min} = 283.68\text{ L/min} \approx 284\text{ L/min}$$ DISTRACTOR RATIONALE: - Option A (0.045 kg/kg, 135 L/min) fails to subtract vapor pressure in the denominator ($P$ instead of $P - P_{ws}$). - Option B (0.142 kg/kg, 426 L/min) assumes saturation at a higher dry-bulb temperature. - Option C (0.068 kg/kg, 204 L/min) mistakenly evaluates vapor pressure at 40°C.
Problem 3
A collection cylinder in a municipal anaerobic digestion facility contains m = 2.50 kg of pure methane gas (CH₄, molecular weight MW = 16.04 kg/kmol, specific gas constant R = 0.5184 kJ/(kg·K)). The gas is initially at state 1 with pressure P₁ = 300.0 kPa and temperature T₁ = 35.0°C (308.15 K). The methane undergoes a quasi-equilibrium polytropic expansion process following PV^1.25 = constant (polytropic index n = 1.25) to a final pressure of P₂ = 120.0 kPa. According to the ideal gas polytropic process relationships: $$T_2 = T_1 \left( \frac{P_2}{P_1} \right)^{\frac{n-1}{n}} \quad \text{and} \quad W = \frac{m R (T_2 - T_1)}{1 - n}$$ calculate the final gas temperature (T₂ in K and °C) and the total boundary work performed by the expanding gas (W in kJ).
- AW = 195.2 kJ; T2 = 275.4 K; Expansion work done by gas
- BW = 267.5 kJ; T2 = 256.6 K; Expansion work done by gascorrect
- CW = 345.0 kJ; T2 = 240.2 K; Expansion work done by gas
- DW = 412.8 kJ; T2 = 225.0 K; Expansion work done by gas
Show the solution
1. FINAL TEMPERATURE (T2): For a polytropic process with ideal gas: $$\frac{n - 1}{n} = \frac{1.25 - 1.00}{1.25} = \frac{0.25}{1.25} = 0.200$$ Pressure ratio: $$\frac{P_2}{P_1} = \frac{120.0\text{ kPa}}{300.0\text{ kPa}} = 0.400$$ Calculate final temperature: $$T_2 = T_1 \left( \frac{P_2}{P_1} \right)^{0.200} = 308.15\text{ K} \times (0.400)^{0.200}$$ $$(0.400)^{0.200} = \exp(0.200 \times \ln(0.400)) = \exp(0.200 \times (-0.91629)) = \exp(-0.183258) = 0.832554$$ $$T_2 = 308.15 \times 0.832554 = 256.552\text{ K} \approx 256.6\text{ K} \quad (-16.6^\circ\text{C})$$ 2. POLYTROPIC BOUNDARY EXPANSION WORK (W): Given mass $m = 2.50\text{ kg}$ and $R = 0.51836\text{ kJ/(kg}\cdot\text{K)}$: $$W = \frac{m \cdot R \cdot (T_2 - T_1)}{1 - n}$$ Temperature change: $$T_2 - T_1 = 256.552\text{ K} - 308.15\text{ K} = -51.598\text{ K}$$ Denominator: $$1 - n = 1.00 - 1.25 = -0.25$$ Compute work: $$W = \frac{2.50\text{ kg} \times 0.51836\text{ kJ/(kg}\cdot\text{K)} \times (-51.598\text{ K})}{-0.25}$$ $$W = \frac{1.2959\text{ kJ/K} \times (-51.598\text{ K})}{-0.25} = \frac{-66.866\text{ kJ}}{-0.25} = +267.46\text{ kJ} \approx 267.5\text{ kJ}$$ (The positive sign confirms boundary work is performed by the expanding gas on the surroundings). DISTRACTOR RATIONALE: - Option A (W = 195.2 kJ) assumes an isothermal process (n = 1.0). - Option C (W = 345.0 kJ) uses air gas constant R = 0.287 kJ/(kg·K) instead of methane. - Option D (W = 412.8 kJ) uses an isentropic index k = 1.30 with inverted temperature differences.