Thermodynamics on the FE Environmental exam

Thermodynamics accounts for 3 of the 110 questions — 2.7% of your exam. It is one of the lighter areas, which makes it a good place to secure quick marks rather than a place to spend weeks.

Questions3
Share of exam2.7%
Rank by weight15/15
In our bank15

What Thermodynamics covers

On the FE Environmental exam this area covers properties of pure substances, ideal and real gases, the first and second laws, closed and open systems, power and refrigeration cycles, entropy, and mixtures.

What the questions look like: An energy balance on a control volume, a cycle efficiency, or a property read from the steam tables.

Worth knowing cold: Identify the system boundary and whether it is closed or open before writing anything. That single decision determines which form of the first law applies.

3 free Thermodynamics practice problems

These come from our FE Environmental bank, written to the same specification as the exam. Try each one before opening the solution.

Problem 1

A municipal eco-district uses a closed-loop geothermal groundwater heat pump to provide heating to a civic center. The groundwater source maintains a constant evaporator temperature of $T_{\text{cold}} = 12.0^\circ\text{C}$ ($285.15\text{ K}$), while the building distribution hydronic system requires a condenser supply temperature of $T_{\text{hot}} = 38.0^\circ\text{C}$ ($311.15\text{ K}$). The building design thermal heating demand is $\dot{Q}_H = 150.0\text{ kW}$. If the actual heat pump achieves an overall Coefficient of Performance (COP) equal to $45.0\%$ of the theoretical Carnot maximum heating COP, what electrical power input $W_{\text{in}}$ (in kW) is required to drive the compressor?

  1. A12.5 kW, assuming an ideal Carnot heat pump without thermodynamic irreversibilities
  2. B67.5 kW, multiplying heating load directly by the 45% efficiency factor
  3. C122.2 kW, reporting the heat absorbed from the geothermal groundwater source
  4. D27.9 kWcorrect
Show the solution

A heat pump delivers thermal heat to a conditioned space by absorbing low-temperature heat from an environmental reservoir (groundwater) and consuming mechanical/electrical work. Step 1: Maximum theoretical Carnot Coefficient of Performance for heating: $\text{COP}_{\text{Carnot, heat}} = \dfrac{T_{\text{hot}}}{T_{\text{hot}} - T_{\text{cold}}} = \dfrac{311.15\text{ K}}{311.15 - 285.15\text{ K}} = \dfrac{311.15}{26.0\text{ K}} = 11.967$. Step 2: Actual operating heating COP accounting for motor, compressor, and heat exchanger irreversibilities: $\text{COP}_{\text{actual}} = 0.450 \times \text{COP}_{\text{Carnot}} = 0.450 \times 11.967 = 5.385$. Step 3: By definition, $\text{COP} = \dfrac{\dot{Q}_H}{W_{\text{in}}}$, where $\dot{Q}_H$ is thermal heat delivered and $W_{\text{in}}$ is electrical work input. Solving for electrical input power: $W_{\text{in}} = \dfrac{\dot{Q}_H}{\text{COP}_{\text{actual}}} = \dfrac{150.0\text{ kW}}{5.385} = 27.854\text{ kW} \approx 27.9\text{ kW}$. Step 4: The thermal energy extracted cleanly from the groundwater is $\dot{Q}_C = \dot{Q}_H - W_{\text{in}} = 150.0 - 27.9 = 122.1\text{ kW}$, saving massive grid power compared to electric resistance heating.

Problem 2

A wet limestone Flue Gas Desulfurization (FGD) spray absorber treats hot, dry combustion gas exiting an industrial boiler. The gas enters the absorber tower at a dry-bulb temperature of T₁ = 160°C with an initial humidity ratio of ω₁ = 0.020 kg H₂O/kg dry gas. In the scrubber, the flue gas undergoes adiabatic saturation by evaporating recirculating slurry water, exiting at its adiabatic saturation (wet-bulb) temperature of Twb = 55°C under complete saturation (100% relative humidity, ϕ = 1.0). The total atmospheric pressure in the scrubber is P = 101.325 kPa. At 55°C, the saturation vapor pressure of water is Pws = 15.76 kPa. If the dry flue gas mass flow rate is m_dry = 50.0 kg/s, calculate the increase in humidity ratio Δω and the required continuous water make-up rate V̇w in L/min (assuming water density ρw = 1,000 kg/m³).

  1. AΔω = 0.045 kg/kg; V̇w = 135 L/min
  2. BΔω = 0.142 kg/kg; V̇w = 426 L/min
  3. CΔω = 0.068 kg/kg; V̇w = 204 L/min
  4. DΔω = 0.095 kg/kg; V̇w = 284 L/mincorrect
Show the solution

1. EXIT SATURATION HUMIDITY RATIO (ω2): At $T_{wb} = 55^\circ\text{C}$ and $P_{ws} = 15.76\text{ kPa}$: $$\omega_2 = 0.622 \frac{P_{ws}}{P - P_{ws}} = 0.622 \times \frac{15.76\text{ kPa}}{101.325 - 15.76\text{ kPa}} = 0.622 \times \frac{15.76}{85.565} = 0.11456\text{ kg }H_2O/\text{kg dry gas}$$ 2. HUMIDITY RATIO INCREASE (Δω): $$\Delta \omega = \omega_2 - \omega_1 = 0.11456 - 0.02000 = 0.09456\text{ kg/kg} \approx 0.095\text{ kg/kg}$$ 3. WATER MAKE-UP EVAPORATION RATE (V̇w): Mass flow rate of evaporated water: $$\dot{m}_w = \dot{m}_{\text{dry}} \times \Delta \omega = 50.0\text{ kg/s} \times 0.09456\text{ kg/kg} = 4.728\text{ kg/s}$$ Volumetric water rate: $$\dot{V}_w = 4.728\text{ kg/s} \times \frac{1\text{ L}}{1.0\text{ kg}} \times 60\text{ s/min} = 283.68\text{ L/min} \approx 284\text{ L/min}$$ DISTRACTOR RATIONALE: - Option A (0.045 kg/kg, 135 L/min) fails to subtract vapor pressure in the denominator ($P$ instead of $P - P_{ws}$). - Option B (0.142 kg/kg, 426 L/min) assumes saturation at a higher dry-bulb temperature. - Option C (0.068 kg/kg, 204 L/min) mistakenly evaluates vapor pressure at 40°C.

Problem 3

A collection cylinder in a municipal anaerobic digestion facility contains m = 2.50 kg of pure methane gas (CH₄, molecular weight MW = 16.04 kg/kmol, specific gas constant R = 0.5184 kJ/(kg·K)). The gas is initially at state 1 with pressure P₁ = 300.0 kPa and temperature T₁ = 35.0°C (308.15 K). The methane undergoes a quasi-equilibrium polytropic expansion process following PV^1.25 = constant (polytropic index n = 1.25) to a final pressure of P₂ = 120.0 kPa. According to the ideal gas polytropic process relationships: $$T_2 = T_1 \left( \frac{P_2}{P_1} \right)^{\frac{n-1}{n}} \quad \text{and} \quad W = \frac{m R (T_2 - T_1)}{1 - n}$$ calculate the final gas temperature (T₂ in K and °C) and the total boundary work performed by the expanding gas (W in kJ).

  1. AW = 195.2 kJ; T2 = 275.4 K; Expansion work done by gas
  2. BW = 267.5 kJ; T2 = 256.6 K; Expansion work done by gascorrect
  3. CW = 345.0 kJ; T2 = 240.2 K; Expansion work done by gas
  4. DW = 412.8 kJ; T2 = 225.0 K; Expansion work done by gas
Show the solution

1. FINAL TEMPERATURE (T2): For a polytropic process with ideal gas: $$\frac{n - 1}{n} = \frac{1.25 - 1.00}{1.25} = \frac{0.25}{1.25} = 0.200$$ Pressure ratio: $$\frac{P_2}{P_1} = \frac{120.0\text{ kPa}}{300.0\text{ kPa}} = 0.400$$ Calculate final temperature: $$T_2 = T_1 \left( \frac{P_2}{P_1} \right)^{0.200} = 308.15\text{ K} \times (0.400)^{0.200}$$ $$(0.400)^{0.200} = \exp(0.200 \times \ln(0.400)) = \exp(0.200 \times (-0.91629)) = \exp(-0.183258) = 0.832554$$ $$T_2 = 308.15 \times 0.832554 = 256.552\text{ K} \approx 256.6\text{ K} \quad (-16.6^\circ\text{C})$$ 2. POLYTROPIC BOUNDARY EXPANSION WORK (W): Given mass $m = 2.50\text{ kg}$ and $R = 0.51836\text{ kJ/(kg}\cdot\text{K)}$: $$W = \frac{m \cdot R \cdot (T_2 - T_1)}{1 - n}$$ Temperature change: $$T_2 - T_1 = 256.552\text{ K} - 308.15\text{ K} = -51.598\text{ K}$$ Denominator: $$1 - n = 1.00 - 1.25 = -0.25$$ Compute work: $$W = \frac{2.50\text{ kg} \times 0.51836\text{ kJ/(kg}\cdot\text{K)} \times (-51.598\text{ K})}{-0.25}$$ $$W = \frac{1.2959\text{ kJ/K} \times (-51.598\text{ K})}{-0.25} = \frac{-66.866\text{ kJ}}{-0.25} = +267.46\text{ kJ} \approx 267.5\text{ kJ}$$ (The positive sign confirms boundary work is performed by the expanding gas on the surroundings). DISTRACTOR RATIONALE: - Option A (W = 195.2 kJ) assumes an isothermal process (n = 1.0). - Option C (W = 345.0 kJ) uses air gas constant R = 0.287 kJ/(kg·K) instead of methane. - Option D (W = 412.8 kJ) uses an isentropic index k = 1.30 with inverted temperature differences.

Find out where you actually stand

A free 20-question diagnostic across every FE Environmental knowledge area, scored in the real exam interface. You get a projected score and the areas costing you the most — so you know whether Thermodynamics is where your time should go at all.

Start the free Environmental diagnostic

Retaking the FE Environmental exam?

Copy the scores from your NCEES diagnostic report and see whether Thermodynamics is where your next attempt gains the most points, or whether another area deserves the time first.

Analyze my diagnostic report

Other FE Environmental knowledge areas

Thermodynamics on other FE exams

The same knowledge area is weighted differently on each exam, and the questions differ with it.