Problem 1
An electric motor drives a high-viscosity polymer mixer, delivering a steady torque of $350\text{ N}\cdot\text{m}$ to the mixer shaft rotating at $180\text{ rpm}$. The motor is connected to a $460\text{ V}$ (line-to-line), 3-phase AC industrial power line. If the motor operates with an efficiency of $\eta = 88.0\%$ and a power factor of $PF = 0.850$, the line current drawn by the motor is most nearly:
- A8.2 A
- B9.4 A
- C11.1 Acorrect
- D14.2 A
Show the solution
Step 1: Calculate the rotational speed in radians per second: $$\omega = 180\text{ rev/min} \times \dfrac{2\pi\text{ rad}}{1\text{ rev}} \times \dfrac{1\text{ min}}{60\text{ s}} = 6\pi = 18.850\text{ rad/s}$$ Step 2: Determine the mechanical output power of the motor: $$P_{mech} = T \omega = 350\text{ N}\cdot\text{m} \times 18.850\text{ rad/s} = 6,597.3\text{ W} = 6.60\text{ kW}$$ Step 3: Determine the electrical input power using motor efficiency: $$P_{elec} = \dfrac{P_{mech}}{\eta} = \dfrac{6,597.3\text{ W}}{0.880} = 7,497.0\text{ W} = 7.50\text{ kW}$$ Step 4: Compute the line current from the 3-phase electrical power formula in the FE Handbook: $$P_{elec} = \sqrt{3} V_L I_L (PF)$$ $$I_L = \dfrac{P_{elec}}{\sqrt{3} V_L (PF)} = \dfrac{7,497.0\text{ W}}{\sqrt{3} \times 460\text{ V} \times 0.850} = \dfrac{7,497.0}{677.23} = 11.07\text{ A} \approx 11.1\text{ A}$$ Distractor Analysis: - Option A (8.2 A) forgets the $\sqrt{3}$ factor and divides by 3. - Option B (9.4 A) ignores the motor efficiency, calculating current from mechanical power alone. - Option D (14.2 A) treats the system as single-phase without the $\sqrt{3}$ term in the denominator.
Problem 2
A thin-walled cylindrical chemical process drum (inside diameter $D_i = 1.18\text{ m}$, wall thickness $t = 10.0\text{ mm} = 0.010\text{ m}$) operates under an internal design gage pressure of $P = 2.00\text{ MPa}$. According to thin-walled pressure vessel stress formulas from the NCEES FE Reference Handbook, the circumferential hoop stress ($\sigma_h$) and the longitudinal axial stress ($\sigma_l$) in the shell wall are most nearly:
- Aσh = 59 MPa, σl = 118 MPa
- Bσh = 118 MPa, σl = 59 MPacorrect
- Cσh = 177 MPa, σl = 88 MPa
- Dσh = 236 MPa, σl = 118 MPa
Show the solution
Step 1: Calculate the circumferential (hoop) stress ($\sigma_h$) from the NCEES FE Reference Handbook: $$\sigma_h = \frac{P D_i}{2 t}$$ $$\sigma_h = \frac{(2.00\text{ MPa})(1.18\text{ m})}{2(0.010\text{ m})} = \frac{2.36\text{ MPa}\cdot\text{m}}{0.020\text{ m}} = 118.0\text{ MPa}$$ Step 2: Calculate the longitudinal (axial) stress ($\sigma_l$): $$\sigma_l = \frac{P D_i}{4 t} = \frac{\sigma_h}{2}$$ $$\sigma_l = \frac{(2.00\text{ MPa})(1.18\text{ m})}{4(0.010\text{ m})} = \frac{2.36}{0.040} = 59.0\text{ MPa}$$ Distractor Analysis: - Option A: Inverts hoop and longitudinal stresses. - Option B: Correct. - Option C: Assumes spherical vessel geometry where $\sigma_h = \sigma_l$. - Option D: Omits the factor of 2 in denominator.
Problem 3
A three-phase electric induction motor drives a centrifugal chemical process pump circulating a glycol solution ($Q = 0.0400\text{ m}^3\text{/s}$, $\rho = 1050\text{ kg/m}^3$). The motor draws $32.0\text{ kW}$ of electrical power from the electrical grid and operates with an energy conversion efficiency of $\eta_m = 92.0\%$. The centrifugal pump operates with a hydraulic mechanical efficiency of $\eta_p = 78.0\%$. The net hydraulic power delivered directly to the flowing fluid ($P_{fluid} = \Delta P \cdot Q$) is most nearly:
- A32.0 kW
- B29.4 kW
- C25.0 kW
- D23.0 kWcorrect
Show the solution
Step 1: Calculate mechanical brake power delivered to the pump shaft: $$P_{shaft} = P_{elec} \cdot \eta_m = (32.0\text{ kW}) \times (0.920) = 29.44\text{ kW}$$ Step 2: Calculate hydraulic power delivered directly to the fluid: $$P_{fluid} = P_{shaft} \cdot \eta_p = (29.44\text{ kW}) \times (0.780) = 22.963\text{ kW} \approx 23.0\text{ kW}$$ Step 3: Verification of combined efficiency: $$\eta_{overall} = \eta_m \cdot \eta_p = 0.920 \times 0.780 = 0.7176 = 71.76\%$$ $$P_{fluid} = (32.0\text{ kW}) \times (0.7176) = 22.96\text{ kW} = 23.0\text{ kW}$$ Distractor Analysis: - Option A: Gross electrical power input ($32.0\text{ kW}$), neglecting all electrical and hydraulic losses. - Option B: Motor shaft power ($29.4\text{ kW}$), omitting pump impeller mechanical and hydraulic losses. - Option C: Applies only pump efficiency to electrical power ($32.0 \times 0.780 = 25.0\text{ kW}$), omitting motor efficiency. - Option D: Correct.